Errors in transfusion medicine.

Abstract

In the past two decades, health services in the developed world have directed much resource toward improving the safety of the blood supply. Blood is collected, tested, and processed within a carefully controlled environment, and quality is assured by rigorous donor selection procedures and increasingly sensitive and sophisticated testing for transfusion-transmitted pathogens. Additional safety strategies implemented by some blood services include leukocyte reduction, bacterial screening, and pathogen inactivation. Thus, the transfusion chain from the donor to the point of issue from the blood center is highly regulated and secure, and transfusion-transmitted infection is an increasingly rare event.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dorothy Stainsby. 2005. Errors in transfusion medicine.. https://doi.org/10.1016/j.atc.2005.01.002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimum blood sampling time windows for parameter estimation in population pharmacokinetic experiments.

Clinical trials requiring the collection of pharmacokinetic information often specify blood samples to be taken at fixed times. This may be feasible when trial participants are in a controlled environment such as in early phase clinical trials, however it becomes problematic in trials where patients are in an out-patient clinic setting such as in late phase drug development. In such a situation it is common to take blood samples when it is convenient for all involved and may result in data that are uninformative. This paper proposes an approach to pharmacokinetic study design that allows greater flexibility as to when blood samples can be taken and still result in data that allows satisfactory parameter estimation. The sampling window approach proposed in this paper is based on determining time intervals around the D-optimum pharmacokinetic sampling times. These intervals are determined by allowing the sampling window design to result in a specified level of efficiency when compared to the fixed times D-optimum design. Several approaches are suggested for dealing with this design problem.

Blood Specimen Collection↗

Newborn screening for hepatorenal tyrosinemia: Tandem mass spectrometric quantification of succinylacetone.

BACKGROUND: False-positive and false-negative results occur in current newborn-screening programs for hepatorenal tyrosinemia, which measure tyrosine concentrations in blood spots, sometimes in combination with other metabolites, including succinylacetone. We present our experience with a newly described method for succinylacetone quantification in routine newborn screening. METHODS: Succinylacetone was extracted from blood spots that had already been extracted with absolute methanol for acylcarnitine and amino acid analysis. The solvent was acetonitrile-water (80:20 by volume) containing formic acid, hydrazine hydrate, and 100 nmol/L 5,7-dioxooctanoic acid as internal standard. Analysis was performed by tandem mass spectrometry in a separate run. RESULTS: Of 61,344 samples, 99.6% had succinylacetone concentrations < or =5 micromol/L. With a cutoff of 10 micromol/L, no false-positive results were obtained. In 2 patients, the succinylacetone concentrations in the dried blood spots from the 36th and 56th hours of life were 152 and 271 micromol/L, respectively, and the tyrosine concentrations were 54 and 129 micromol/L. Hepatorenal tyrosinemia was subsequently confirmed in both patients. Retrospective analysis of the neonatal screening samples of 2 additional known patients revealed increased succinylacetone concentrations of 46 and 169 micromol/L, respectively. CONCLUSIONS: Tandem mass spectrometric quantification directly from residual blood spots is a useful method for the early detection of hepatorenal tyrosinemia in newborn-screening programs.

Blood Specimen Collection↗

Commercial enzyme immunoassay adapted for the detection of antibodies to hepatitis C virus in dried blood spots.

BACKGROUND: Dried blood spots (DBS) provide a convenient method for blood sample collection in many settings where the prevalence of infection with hepatitis C virus (HCV) is increasing. Consequently, HCV assays are required that produce reliable results using samples derived from DBS. OBJECTIVES AND STUDY DESIGN: The optimum buffer for the elution of samples from DBS was selected and the performance of a commercial enzyme immunoassay (EIA) was evaluated using these DBS eluates and paired plasma samples. RESULTS: DBS with paired plasma samples were compared using this modified commercial EIA, which was found to have an estimated sensitivity and specificity of approximately 100% for detecting anti-HCV antibodies in DBS. CONCLUSION: A DBS-based assay for the detection of antibodies to HCV will prove valuable for collecting epidemiological data in the field or in under resourced settings.

Blood Specimen Collection↗