PubMed Health⌕ Search

PubMed · 15936693

Expiratory asynchrony.

Abstract

Expiratory asynchrony is a universal phenomenon, and expiratory synchrony occurs only by chance. Expiratory asynchrony exists in all breath modes and has a significant impact on the patient's work of breathing and the weaning process. Advancements in ventilator designs and basic physiologic science could lead to the improvement of the expiratory asynchrony.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hong-Lin Du, Yoshitsugu Yamada. 2005. Expiratory asynchrony.. https://doi.org/10.1016/j.rcc.2005.02.001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Time course of exhaled hydrogen peroxide and nitric oxide during chemotherapy.

This study was designed to assess the effect of differential leukocyte depletion during chemotherapy by monitoring the levels of exhaled hydrogen peroxide H2O2 and nitric oxide (F(eNO)) present. In 39 patients with lung cancer (chronic obstructive pulmonary disorder up to stage II, median forced expiratory volume in one second 78% predicted), measurements were performed before a cycle of therapy (day 1), at least once during the cycle (day 8: n = 34; day 15: n = 19), and afterwards (days 21-29). There were significant changes in the level of H2O2, F(eNO) and peripheral blood cell differentials over the visits. The level of H2O2 was decreased only on day 15, with a median (difference between the upper and lower quartiles) fall of 31 (57)%, while F(eNO) was reduced only on day 8, by 22 (40)%. Neutrophil numbers were unchanged on day 8 and decreased by 59 (48)% on day 15, while monocyte numbers were decreased on day 8 by 87 (39)%. On days 21-29, values had returned to baseline. Taken together with previous findings, the parallel course of levels of exhaled hydrogen peroxide and neutrophil counts suggests that a major part of exhaled hydrogen peroxide is due to neutrophils via the conducting airways. In contrast, the production of exhaled nitric oxide seems to be primarily associated with monocytes.

Exhalation↗

Percutaneous access to upper pole renal stones: role of prone 3-dimensional computerized tomography in inspiratory and expiratory phases.

PURPOSE: We evaluated the role of noncontrast, prone position, inspiratory and expiratory 3-dimensional spiral computerized tomography (PIE-CT) for preoperative planning of percutaneous treatment in patients with complex upper pole renal calculi. MATERIALS AND METHODS: In this pilot study a total of 6 renal units in 4 women and 1 man with complex upper pole calculi who were candidates for percutaneous nephrolithotomy were evaluated with thin section PIE-CT. With the patient imaged in the prone position percutaneous access was simulated under 4 potential access conditions, including subcostal and intercostal, in inspiration and expiration. Each potential access was then deemed transpleural or extrapleural and minimally angulated or severely angulated cephalad. RESULTS: PIE-CT was performed uneventfully in all patients. Ideal nonangulated extrapleural percutaneous access was deemed possible in 5 of 6 renal units. However, inspiratory plus expiratory phases were necessary to identify the most suitable access site. In 2 renal units only 1 safe access site was identified. No pulmonary complications were noted in any of these patients. In 1 renal unit no suitable access could be identified and this patient was treated with laparoscopic caliceal diverticulectomy. CONCLUSIONS: Thin section PIE-CT offers 3-dimensionally rendered images that clearly demonstrate anatomical relationships among the kidney, calculi, pleura, diaphragm, ribs and surrounding organs. In this pilot study PIE-CT provided useful data for planning urological intervention for complex upper pole renal stones. This study also suggests that generalizations regarding the safety of upper pole access in the inspiratory or expiratory phase are not warranted.

Exhalation↗

Volumetric expiratory HRCT imaging with MSCT.

Expiratory HRCT is a powerful adjunct to inspiratory HRCT for detecting various small airway diseases. Current standard expiratory HRCT protocol consists of a limited number of non-contiguous scans at selected levels. We have developed a new volumetric expiratory HRCT protocol that allows volumetric data acquisition of lungs both at end-inspiration and end-expiration. By reducing the x-ray tube current, the radiation dose of this new protocol is equivalent to the standard expiratory HRCT protocol at our institution. This volumetric expiratory HRCT has been applied in patients with diffuse lung disease with small airway abnormalities. In this review, we describe: (1) technical considerations of VEHRCT including dose reduction, (2) the advantages of contiguous scans and multiplanar reformations, (3) clinical application of volumetric expiratory HRCT in various diffuse lung diseases, and (4) future directions including computational qualitative assessment of lung biomechanics.

Exhalation↗