PubMed Health⌕ Search

PubMed · 15940422

Modeling and optimization of high-sensitivity, low-volume microfluidic-based surface immunoassays.

Abstract

Microfluidics are emerging as a promising technology for miniaturizing biological assays for applications in diagnostics and research in life sciences because they enable the parallel analysis of multiple analytes with economy of samples and in short time. We have previously developed microfluidic networks for surface immunoassays where antibodies that are immobilized on one wall of a microchannel capture analytes flowing in the microchannel. This technology is capable of detecting analytes with picomolar sensitivity and from sub-microliter volume of sample within 45 min. This paper presents the theoretical modeling of these immunoassays where a finite difference algorithm is applied to delineate the role of the transport of analyte molecules in the microchannel (convection and diffusion), the kinetics of binding between the analyte and the capture antibodies, and the surface density of the capture antibody on the assay. The model shows that assays can be greatly optimized by varying the flow velocity of the solution of analyte in the microchannels. The model also shows how much the analyte-antibody binding constant and the surface density of the capture antibodies influence the performance of the assay. We then derive strategies to optimize assays toward maximal sensitivity, minimal sample volume requirement or fast performance, which we think will allow further development of microfluidic networks for immunoassay applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin Zimmermann, Emmanuel Delamarche, Marc Wolf, Patrick Hunziker. 2005. Modeling and optimization of high-sensitivity, low-volume microfluidic-based surface immunoassays.. https://doi.org/10.1007/s10544-005-1587-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune complexes suppress IFN-gamma signaling by activation of the FcgammaRI pathway.

Antigen-driven immune responses are modulated by immune complexes (ICs), in part through their ability to inhibit IFN-gamma-dependent MHC Class II expression. We have demonstrated previously that ICs dramatically inhibit IFN-gamma-induced activation of human monocytes through the suppression of the JAK/STAT signaling pathway. In the current study, we further explore the mechanisms by which ICs regulate IFN-gamma activation of human monocytes. Consistent with previous studies in monocytes pretreated with ICs, there was a reduction in steady-state levels of RNA by real-time RT-PCR of the IFN-inducible protein 10 gene as well as the FcgammaRI gene. Pull-down assays confirm that IC pretreatment inhibits IFN-gamma-induced STAT1 phosphorylation without affecting the ability of STAT1 to bind to the STAT1-binding domain of the IFN-gamma receptor. In addition, the inhibitory function of ICs was reduced when cells from the FcR common gamma-chain knockout mice were used, supporting the role of the FcgammaRI in this inhibitory pathway. It is unexpected that ICs also require the phosphatase Src homology-2-containing tyrosine phosphatase 1 (SHP-1) to inhibit IFN-gamma induction, as demonstrated by studies with cells from the SHP-1 knockout (motheaten) mice. These data suggest a mechanism of IC-mediated inhibition of IFN-gamma signaling, which requires the ITAM-containing FcgammaRI, as well as the ITIM-dependent phosphatase SHP-1, ultimately resulting in the suppression of STAT1 phosphorylation.

Antigen-Antibody Complex↗

Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase.

In order to increase the sensitivity of liquid chromatography/mass spectrometry (LC/MS) assays of recombinant proteins for pharmacokinetics studies, we have developed an immuno-mass spectrometry assay for EPI-hNE4, a 6237 Da protein currently developed for respiratory distress syndromes. After immunocapture of the analyte in human plasma with magnetic beads coated with anti-EPI-hNE4 antibodies, the intact protein was eluted and separated in reversed-phase LC and then analysed by tandem mass spectrometry (MS/MS) in selected reaction monitoring (SRM) mode. The problem of analytical interference due to endogenous binding antibodies was addressed by successive steps of acidification and neutralisation before immunocapture. Furthermore, potential variations in the recovery of analyte during sample extraction were compensated for by addition of an internal standard recognised by the antibodies. The precision of the assay remained therefore below 15%. A significant increase in assay sensitivity was achieved since the extraction step allowed sample concentration and removal of matrix components interfering with the electrospray ionisation process. Using 0.4 mL of plasma, a limit of quantification at 0.5 ng/mL (80 pM) was reached, which represents a 10-fold improvement in sensitivity over our previous work using sample precipitation. This technique was able to monitor EPI-hNE4 kinetics in the plasma of human subjects for 36 h after an intravenous administration of 0.125 mg/kg.

Antigen-Antibody Complex↗

Antibody arrays for quantitative immunophenotyping.

Detection of multiple surface antigens expressed on living cell is an important step for cell processing and clinical diagnosis. Here we describe the preparation of antibody arrays that allow parallel detection of multiple surface antigens through affinity binding of living cells. An antibody array was fabricated by photo-assisted patterning of an alkanethiol monolayer formed on a gold-coated glass plate and subsequent immobilization of antibodies specific for cell surface antigens in an array format. We demonstrate here that rapid phenotyping can be performed on the array for both adhesion-dependent and non-dependent cells by direct cell binding assays. The density of bound cells on each antibody spot was in accordance with their contents in an original suspension. This result suggests the feasibility of the array-based method for quantitative assessment of multiple antigen expression. These findings will serve to extend the range of fundamental and clinical applications of antibody arrays.

Antigen-Antibody Complex↗