Fluorescence correlation microscopy with real-time alignment readout.

Abstract

In confocal fluorescence correlation microscopy (FCM) it is important to ensure that the correlation measurement is actually performed at the chosen location of the three-dimensional image of the specimen. We present a confocal FCM design that provides an automatic real-time readout of the location in the confocal microscopic image, which is aligned with the detector of the fluorescence correlation spectrometer. The design accomplishes this without using any special positioning device. The design is based on an apertured fluorescence detector placed close to the back aperture of the objective lens and can be easily incorporated into virtually any confocal microscope. We demonstrate the method by performing FCM measurements of a dye diffusing on a cell membrane.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sanjeev Kumar Kaushalya, Jayaprakash Balaji, Kanchan Garai, Sudipta Maiti. 2005-06-01. Fluorescence correlation microscopy with real-time alignment readout.. https://doi.org/10.1364/ao.44.003262

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of the electrolyte concentration on cation binding in aqueous surfactant solutions.

Electrospray ionisation mass spectrometry (ESI-MS) is used for the qualitative and quantitative study of ion binding to interfaces. The ESI-MS measurements are carried out in aqueous solutions of sodium dodecyl sulphate (SDS) in the presence of NaCl, NH(4)ClO(4) , KCl, or Mg(ClO(4))(2) . The effect of the electrolyte concentration on the fractions, y(cation(+) ), of the DS(-) monomers bound to the cations is shown. Moreover, the binding stability of different cations with DS(-) monomers is determined versus the electrolyte concentration. This stability and the y(Na(+) ) values (the Na(+) ions derived from SDS), estimated in the presence of a given electrolyte, are quantitatively correlated with the electrolyte cation effect on the water structure. We also present calibration curves from which the molar concentrations of the sodium ions (derived from SDS) and of the other cations (derived from the electrolyte), bound to the SDS-micelle surface at a given electrolyte concentration, can be obtained. Besides, specific ion effects (Hofmeister effects) are considered for 1:1 electrolytes.

Calibration↗

Rapid determination of total solanesol in tobacco leaf by ultrasound-assisted extraction with RP-HPLC and ESI-TOF/MS.

A reliable and rapid method based on high-performance liquid chromatography (HPLC-UV) and positive ion electrospray-time of flight mass spectrometry (ESI-TOF/MS) has been developed for the characterization and quantification of solanesol in extracts of tobacco leaves from different sources. The solanesol was extracted from tobacco leaf via saponification and ultrasonic-assist extraction, and the extraction conditions were optimized. The HPLC conditions are as following: Hypersil C(4) (4.6 mm x 150 mm, 5 microm) column, acetonitrile and water as mobile phase, flow-rate is 0.8 ml/min, detection length of UV is 202 nm, injection volume is 10 microl. The results indicated that the developed HPLC method is simple, sensitive and reliable for the determination of solanesol in tobacco leaves with a linear dynamic range of 3.65-4672 ng, a detection limit of 1.83 ng, and an average recovery of 98.7%. The method has been applied to analyze and compare different tobacco samples. The results show that the solanesol content in samples of different geographic locations varies widely from 0.20 to 1.50%. When different parts of the tobacco plant are compared, the top parts of the leaves are more abundant in solanesol content than those of lower parts.

Calibration↗