Abstract

Ultra-high molecular weight polyethylene (UHMWPE) has been used as a bearing surface in total hip arthroplasty for nearly 40 years. Early failures have been attributed to gamma irradiation in air sterilization, poor implant design, and high patient activity. Currently available implants address the problems of gamma irradiation in air by using sterilization methods that avoid oxidative degradation. Previous efforts to modify UHMWPE, including carbon reinforcement, hot isostatic pressure, and heat pressing, have not resulted in improved clinical performance. More recently, highly cross-linked UHMWPEs have been developed that markedly reduced wear in hip simulators. However, cross-linking also reduces the mechanical properties, including fatigue crack propagation resistance. Although early clinical results with highly cross-linked UHMWPE are favorable, longer follow-up will be necessary to determine whether the results of in vitro testing accurately reflect long-term in vivo behavior.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael D Ries. 2005. Enhanced polyethylene implants: have we been there before?. https://pubmed.ncbi.nlm.nih.gov/15948446/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

In Europe and the USA combined, over half a million people had a hip joint replaced in 2005, contributing to the increasing number of radiotherapy patients with metallic hip prostheses. The treatment plan for external beam radiation therapy is based on the delineation of the anatomy in the planning CT scan. When implanted objects of high atomic number (Z) material are present, however, severe image artefacts are generated in conventional CT, strongly hindering the ability to delineate some organs. This is particularly the case for the planning of prostate patients with hip prostheses. This short communication presents the use of a new imaging modality, megavoltage cone-beam CT, to complement the regular CT for target definition of prostate cancer treatment of patients with hip replacements.

Hip Prosthesis↗

Stem damage during implantation of modular hip prostheses.

Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to assess if stem holders of modular prostheses can induce any stem damage, and if so, to identify the features that provide minimal damage. Two different stem holder connector designs were investigated. The surface of the stem cavity was inspected to identify the damage caused by the use of the two connectors after a simulated surgical handling. Both connectors induced some damage, with significantly more damage being caused by a supposedly improved design. Scars due to contact with the stem holder were observed on the stem cavity surface. This may be sufficient to trigger increased fretting damage during service life, causing the production of fretting debris.

Hip Prosthesis↗