PubMed Health⌕ Search

PubMed · 15948679

Pathologic tooth migration.

Abstract

Pathologic tooth migration (PTM) is a common complication of moderate to severe periodontitis and is often the motivation for patients to seek periodontal therapy. In this review of the literature, available information concerning prevalence, etiology, treatment, and prevention of pathologic tooth migration is summarized. Prevalence of PTM among periodontal patients has been reported to range from 30.03% to 55.8%. A survey of the literature regarding chief complaints of periodontal patients support these high prevalence findings. The etiology of PTM appears to be multifactorial. Periodontal bone loss appears to be a major factor in the etiology of PTM. Many aspects of occlusion can contribute to abnormal migration of teeth, and more than one of those factors may be present in an individual patient. Soft tissue forces of the tongue, cheeks, and lips are known to cause tooth movement and in some situations can cause PTM. Also considered important in the etiology of PTM is pressure produced from inflammatory tissues within periodontal pockets. Because extrusion is a common form of PTM, clinical observations support the theory that eruption forces sometimes play a role in the etiology of PTM. Many oral habits have been associated with PTM which are often difficult for the therapist to detect. Most cases of severe PTM require a team approach to achieve success. Periodontal, orthodontic, and prosthodontic treatment are often required. Many patient variables enter into the selection of treatment for PTM. In early stages of PTM, spontaneous correction of migrated teeth sometimes occurs after periodontal therapy. Light intrusive forces are used successfully to treat extrusion and flaring forms of PTM. Based on the literature reviewed, it appears that many cases of PTM could be prevented through the early diagnosis and treatment of periodontal disease, occlusal contributing factors, gingival enlargement, and oral habits.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael A Brunsvold. 2005. Pathologic tooth migration.. https://doi.org/10.1902/jop.2005.76.6.859

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Material characteristics of a novel shrinkage-free ZrSiO(4) ceramic for the fabrication of posterior crowns.

OBJECTIVE: To confirm the clinical applicability of a novel ZrSiO(4) (zircon) based shrinkage-free ceramic material, the flexural strength, fracture toughness and chemical solubility were tested. In addition, the fracture load of full crowns made from this material was tested after cyclic thermomechanical loading. METHODS: Flexural strength of 12 specimens was measured using a biaxial bending test. Fracture toughness was measured using 10 slotted box shaped specimens. The specimens were fractured using a universal testing machine; fracture loads were recorded. A chemical solubility test was performed in accordance with ISO norm 6872. Additionally, 32 ZrSiO(4) all-ceramic crowns were fabricated on extracted caries-free human molars. Sixteen Empress 2 and 16 PFM crowns served as a reference control. After artificial aging of 1.2 million cycles in the chewing simulator, the survival rate of the crowns was determined. The fracture load of all surviving specimens was obtained by loading the crowns until fracture in a universal testing machine. RESULTS: A flexural strength of 328MPa was found. The fracture toughness of the ZrSiO(4) ceramic was 5.16MPam(0.5). The chemical solubility amounted to 7.2microg/cm(2). All specimens survived the chewing simulation (survival rate: 100%); no crowns had to be re-cemented. A mean fracture strength of 1790N was found for Everest HPC for Empress 2 crowns, 1715N for Empress 2 crowns and 2416N for PFM crowns. Fracture loads of PFM crowns were significantly higher than for Empress 2 crowns (P=0.032) as well as ZrSiO(4)-crowns (P=0.007). There was no significant difference between ZrSiO(4)-crowns and Empress 2 crowns (P=0.743). SIGNIFICANCE: At the present stage, Everest HPC can be recommended for the fabrication of single crowns as an alternative to conventional PFM and other all-ceramic crowns, because its fracture strength exceeds average masticatory forces in the posterior region.

Bite Force↗

Efficient 3D finite element analysis of dental restorative procedures using micro-CT data.

OBJECTIVES: This investigation describes a rapid method for the generation of finite element models of dental structures and restorations. METHODS: An intact mandibular molar was digitized with a micro-CT scanner. Surface contours of enamel and dentin were fitted following tooth segmentation based on pixel density using an interactive medical image control system. Stereolithography (STL) files of enamel and dentin surfaces were then remeshed to reduce mesh density and imported in a rapid prototyping software, where Boolean operations were used to assure the interfacial mesh congruence (dentinoenamel junction) and simulate different cavity preparations (MO/MOD preparations, endodontic access) and restorations (feldspathic porcelain and composite resin inlays). The different tooth parts were then imported in a finite element software package to create 3D solid models. The potential use of the model was demonstrated using nonlinear contact analysis to simulate occlusal loading. Cuspal deformation was measured at different restorative steps and correlated with existing experimental data for model validation and optimization. RESULTS: Five different models were validated by existing experimental data. Cuspal widening (between mesial cusps) at 100 N load ranged from 0.4 microm for the unrestored tooth, 9-12 microm for MO, MOD cavities, to 12-21 microm for endodontic access cavities. Placement of an MOD adhesive restoration in porcelain resulted in 100% cuspal stiffness recovery (0.4 microm of cuspal widening at 100 N) while the composite resin inlay allowed for a partial recuperation of cusp stabilization (1.3 microm of cuspal widening at 100 N). SIGNIFICANCE: The described method can generate detailed and valid three dimensional finite element models of a molar tooth with different cavities and restorative materials. This method is rapid and can readily be used for other medical (and dental) applications.

Bite Force↗

Analysis of mechanical stress in reconstruction plates for bridging mandibular angle defects.

INTRODUCTION: The objective of the present study was to evaluate the mechanical stress in reconstruction plates and the screw-plate-bone interface used in bridging a mandibular angle defect by means of the finite element method (FEM). The influence of plate geometry as well as the configuration and the diameter of the screws on the mechanical stress distribution was to be determined at the same time and was used as the basis for developing suggestions to optimize the design of the reconstruction plates. MATERIAL: Based on the geometrical data of a human mandible, an angle defect bridged by a titanium reconstruction plate was generated and exposed to chewing force. First a reconstruction plate was tightly fixed with M2.7 titanium screws. Then, plate design, screw configuration and screw diameter were varied. The mechanical stress was calculated according to von Mises stress hypothesis. RESULTS: In the standard reconstruction plate, the result of the finite element analysis revealed stress resulting from the simulated functional loadings which far exceeded the strengths of the components. Possible clinical consequences could be a fatigue fracture of the plate itself, gradual loosening of the osteosynthesis screws and loss of bone. The stress can be reduced to less than half by increasing the diameter of the screw threads 1.5 fold. CONCLUSION: Maximizing the interface between bone and reconstruction plate had a favourable effect. As a consequence of the large interface and a triangular or square configuration of the screws, the stresses could be substantially reduced, the plate could be made thinner and thus better adapted to the mandible. As a preliminary result, the newly designed reconstruction plate could be thinned in areas subject to less mechanical stress.

Bite Force↗