Mitral valve function and chordal force distribution using a flexible annulus model: an in vitro study.

Abstract

Since variations in annular motion/shape and papillary muscle displacement have been observed in studies of dilated cardiomyopathy and ischemic mitral regurgitation, the objective of this study was to investigate the effects of annular motion/flexibility and papillary muscle displacement on chordal force and mitral valve function. Six human mitral valves were studied in a left heart simulator using a flexible annular model. Mitral flow, trans-mitral pressure and chordae tendineae tension were monitored online in normal and pathophysiologic papillary muscle positions. The flexible annulus model showed a significant increase in mitral regurgitation volume (p < 0.05) when compared to static annuli models. Furthermore, there was a significant increase of force on the basal chords compared to the force present with the static annuli models. Utilizing the flexible annulus model, papillary muscle displacement significantly increased the force on the anterior strut, posterior intermediate and commissural chords. (1) Papillary muscle displacement increases the tension on the intermediate chords inducing tenting of the leaflets and subsequent regurgitation. (2) The tension on the intermediate and marginal chords is relatively insensitive to annular motion, whereas tension on the basal chords is directly affected by annular motion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jorge Hernan Jimenez, Dennis Dam Soerensen, Zhaoming He, Jennifer Ritchie, Ajit P Yoganathan. 2005. Mitral valve function and chordal force distribution using a flexible annulus model: an in vitro study.. https://doi.org/10.1007/s10439-005-1512-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A population-based study of cancer incidence in solid organ transplants from donors at various risk of neoplasia.

A population-based cohort study of recipients of organs from donors with a recognized history or active cancer has been conducted by linking the Italian National Registry of Transplanted Patients and the National Registry of Donors with Neoplasia Risk. Between 2002 and 2004, 8,198 solid organ transplants have been performed in Italy, 108 of them with organs from 59 cadaveric donors with various risk of neoplasia. There were two reported cases of nonmelanoma skin cancer during the follow up of the transplanted patients, which lasted 27.6+/-11.3 months (234 patient-years). In our study, recipients of organs from donors with various degree of neoplasia risk are exposed to a low risk of cancer transmission.

Cadaver↗

[Primary stability of the capsule-labrum complex after reconstruction with the Mitek Bioknotless anchor system in human cadaver models].

BACKGROUND: This study examines the postoperative stability of the Mitek Bioknotless anchor system with biomechanical draw-out pulling in human cadaver shoulders. METHOD: With simulation of anterior shoulder dislocation a test group (n=10, Ø 45 years) was tested against a native group (n=8, Ø 47 years). All shoulders were dissected up to the passive stabilizers. In the test group an artificial Bankart lesion was created and repaired with three Mitek Bioknotless anchors. The humeri of both groups were fixed in 60 degrees glenohumeral abduction and 90 degrees external rotation and then dislocated in a ventral direction. For evaluation purposes the ultimate draw-out strength, mode of failure, translation of humeral head, capsular slope, and bone density in the test group were measured. RESULTS: In the test group the ultimate strength was a median of 937 N (min. 554 N, max. 1,294 N) with 28 bony anchor dislocations, 1 suture rupture, and 1 capsular rupture, and in the native group with 6 Bankart and 2 HAGL lesions it was 1,214 N (708 N, 1,471 N). The bone density showed a positive correlation to the draw-out strength regarding cortical density and total density. CONCLUSION: Regarding the high draw-out strength the Mitek Bioknotless anchor system provides enough stability for early functional treatment.

Cadaver↗