[How endoscopy has changed in recent 60 years].

Abstract

Sixty years ago only semi flexible instruments were used for the endoscopic examination of the gastrointestinal tract. They were developed by the German physician Rudolf Schindler together with George Wolf, the producer of medical instruments in 1932. They construct optical gastroscope with a system of lenses in the flexible distal end and with the rigid metallic proximal part. Those instruments were used in gastroscopy till the sixties when the era of fibroendoscopy with the use of glass fibre optic has started. In 1957 Basil Hirschowitz with his co-workers introduced a flexible gastroscope--a fibroscope. The next years brought improvement in the size of image, its brilliancy, possibility to control the distal end and a bioptic channels was added. Working length was elevated and since 1970 the instrument has been used as ezofago-gastro-duodenoscope. At the end of millennium a new technology was developed--videoendoscopy. Experience with the prototype of videoendoscope was published in 1984 (Sivak a Fleischer, Classen a Phillip). In the nineties of the previous century Paul Swain constructed the first prototype of wireless endoscopic capsule. A single chip camera with low electricity consumption was presented in 2000. Endoscopy has developed in recent years considerably and its progress will definitely continue.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Lukás. 2005. [How endoscopy has changed in recent 60 years].. https://pubmed.ncbi.nlm.nih.gov/15981984/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Clinical experience with the hygienic reprocessing of rigid endoscopes lacking a working channel with reference to practicability in clinical routine].

BACKGROUND: Contaminated medical products may be vectors for infections. A safe disinfection method for the optical instruments used by ENT specialists is undoubtedly needed. So far, a standard method that sufficiently covers the risk of infection for patients and medical staff alike, while serving the need of practicability in daily routine, has not been established. PATIENTS AND METHODS: In the ENT departments of the Mannheim and Kaiserslautern hospitals, a study on the practicability of disinfection rigid optical instruments lacking working channels was conducted using cleaning and disinfection automats. A total of 735 patients were examined (Hopkins 30 degrees and 70 degrees) and the endoscopes subsequently sterilized using a cleaning and disinfection automat. RESULTS: Each cleaning cycle took about 40 min. Examining 70-100 patients a day, a minimum of eight 70 degrees Hopkins endoscopes would be needed. CONCLUSION: The sterilization of medical products such as endoscopes is the best practice, but certain hindrances, such as loss of time and costs involved, complicate its general application.

Endoscopes, Gastrointestinal↗