PubMed Health⌕ Search

PubMed · 15987130

Glyphosate immunosensor. Application for water and soil analysis.

Abstract

A fully automated immunosensor for the herbicide glyphosate has been developed on the basis of the immunocomplex capture assay protocol. The sensor carries out on-line analyte derivatization prior to the assay and uses a selective anti-glyphosate serum, a glyphosate peroxidase enzyme tracer, and fluorescent detection. Under optimal conditions, the detection limit achieved is 0.021 microg/L with an analysis rate of 25 min per assay, autonomy of more than 48 h, and sensor reusability >500 analytical cycles. The immunosensor is able to discriminate structurally related molecules, such as aminomethylphosphonic acid, the main metabolite of glyphosate, and other related herbicides, such as glufosinate and glyphosine. Interferences from naturally occurring species (anions, cations, and humic substances) and their elimination were also studied. The immunosensor has been successfully applied to water and soil sample analysis, with good recoveries at levels lower than 1 microg/L. Results obtained with the immunosensor correlate well with data from a magnetic particle ELISA and LC/LC/MS chromatographic method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Miguel Angel González-Martínez, Eva María Brun, Rosa Puchades, Angel Maquieira, Kristy Ramsey, Fernando Rubio. 2005-07-01. Glyphosate immunosensor. Application for water and soil analysis.. https://doi.org/10.1021/ac048431d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A knowledge-based move set for protein folding.

The free energy landscape of protein folding is rugged, occasionally characterized by compact, intermediate states of low free energy. In computational folding, this landscape leads to trapped, compact states with incorrect secondary structure. We devised a residue-specific, protein backbone move set for efficient sampling of protein-like conformations in computational folding simulations. The move set is based on the selection of a small set of backbone dihedral angles, derived from clustering dihedral angles sampled from experimental structures. We show in both simulated annealing and replica exchange Monte Carlo (REMC) simulations that the knowledge-based move set, when compared with a conventional move set, shows statistically significant improved ability at overcoming kinetic barriers, reaching deeper energy minima, and achieving correspondingly lower RMSDs to native structures. The new move set is also more efficient, being able to reach low energy states considerably faster. Use of this move set in determining the energy minimum state and for calculating thermodynamic quantities is discussed.

Glycine↗

Fluorescent sensing layer for the determination of L-malic acid in wine.

An enzymatic method for determining L-malic acid in wine based on an L-malate sensing layer with nicotinamide adenine dinucleotide (NAD+), L-malate dehydrogenase (L-MDH) and diaphorase (DI), immobilized by sol-gel technology, was constructed and evaluated. The sol-gel glass was prepared with tetramethoxysilane (TMOS), water and HCl. L-MDH catalyzes the reaction between L-malate and NAD+, producing NADH, whose fluorescence (lambdaexc=340 nm, lambdaem=430 nm) could be directly related to the amount of L-malate. NADH is converted to NAD+ by applying hexacyanoferrate(III) as oxidant in the presence of DI. Some parameters affecting sol-gel encapsulation and the pH of the enzymatic reaction were studied. The sensing layer has a dynamic range of 0.1-1.0 g/L of L-malate and a long-term storage stability of 25 days. It exhibits acceptable reproducibility [sr(%) approximately 10] and allows six regenerations. The content of L-malic acid was determined for different types of wine, and polyvinylpolypyrrolidone (PVPP) was used as a bleaching agent with red wine. The results obtained for the wine samples using the sensing layer are comparable to those obtained from a reference method based on UV-vis molecular absorption spectrometry, if the matrix effect is corrected for.

Glycine↗

Non-ketotic hyperglycinemia is usually not detectable by tandem mass spectrometry newborn screening.

Diagnosis of Non-Ketotic Hyperglycinemia by MSMS newborn screening might benefit patients with post-neonatal presentation. We screened 733,527 babies over eight years, and nine babies were subsequently diagnosed with NKHG. Two had newborn glycine levels above our cut-off and presented within 72 h. The remaining patients could not have been diagnosed by newborn screening without an unacceptably high recall rate. We conclude that babies with NKHG are not usually identifiable by current newborn screening strategies.

Glycine↗