PubMed Health⌕ Search

PubMed · 16000532

Running performance has a structural basis.

Abstract

The body sizes of highly adapted human and other mammalian runners vary in accordance with specific performance needs. Sprint specialists are relatively massive and muscular while endurance specialists are conspicuously limited both in body and in muscle mass. We hypothesized that the greater body masses of faster specialists are directly related to the greater ground support forces required to attain faster running speeds. Using human runners as a test case, we obtained mean values for body mass, stature and racing speed for the world's fastest 45 male and female specialists, respectively, over the past 14 years (1990-2003) at each of eight standard track racing distances from 100 to 10,000 m. Mass-specific ground support force requirements were estimated from racing speeds using generalized support force-speed relationships derived from 18 athletic subjects. We find a single relationship between mass, stature and event-specific ground support force requirements that spans the entire continuum of specializations and applies both to male and to female runners [body mass (kg) = mass-specific support force x stature2 (m) x a constant; N = 16 group means, R2 = 0.97; where the ideal mass constant, D = 10 kg m(-2)]. We conclude that running performance has a common structural basis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter G Weyand, J Adam Davis. 2005. Running performance has a structural basis.. https://doi.org/10.1242/jeb.01609

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗

Percutaneous vertebroplasty and kyphoplasty for the stand-alone augmentation of osteoporosis-induced vertebral compression fractures: present status and future directions.

Enormous research efforts are being expended on two minimally invasive procedures: percutaneous vertebroplasty (VP) and kyphoplasty (KP). The present report, which is a detailed critical review of VP and KP that emphasizes their biomechanics aspects, is divided into six parts. In the first two parts, succinct descriptions are given of osteoporosis-induced vertebral body (VB) compression fractures as the underlying pathology to be treated with VP and KP, the theory of VP and KP, and the techniques used in performing these procedures. Concerns about VP and KP, such as the high radiation exposure burden that may be imposed on both patient and medical personnel and extravasation of the injectable bone cement, are discussed in the third part. Detailed discussions of fourteen issues/questions, such as the extent to which VP or KP affects various biomechanical measures of the augmented VB and those adjacent to it and the appropriate volume of the cement to use, are presented in the fourth part. Ideas for future research, such as development of a new generation of injectable bone cements and identification of an appropriate animal model, are covered in the fifth part. The final section contains a summary of the most salient points/observations made in the report.

Biomechanical Phenomena↗

Compliant leg behaviour explains basic dynamics of walking and running.

The basic mechanics of human locomotion are associated with vaulting over stiff legs in walking and rebounding on compliant legs in running. However, while rebounding legs well explain the stance dynamics of running, stiff legs cannot reproduce that of walking. With a simple bipedal spring-mass model, we show that not stiff but compliant legs are essential to obtain the basic walking mechanics; incorporating the double support as an essential part of the walking motion, the model reproduces the characteristic stance dynamics that result in the observed small vertical oscillation of the body and the observed out-of-phase changes in forward kinetic and gravitational potential energies. Exploring the parameter space of this model, we further show that it not only combines the basic dynamics of walking and running in one mechanical system, but also reveals these gaits to be just two out of the many solutions to legged locomotion offered by compliant leg behaviour and accessed by energy or speed.

Biomechanical Phenomena↗