Three-dimensional echocardiography.

Abstract

Three-dimensional (3-D) echocardiography has been an important research goal ever since the introduction of two-dimensional (2-D) echocardiography. Most approaches towards 3-D echocardiography were off-line and based on the sequential rotational scanning and acquisition of multiple cross-sectional images together with external or internal reference systems. These approaches were limited by long acquisition and analysis time in combination with poor image quality. Recently, improvements in the matrix array technology have significantly increased spatial and temporal resolution of second-generation real-time 3-D transducers. Clinical use of modern 3-D echocardiography is boosted by the marked reduction in acquisition time and the unique possibility of on-line rendering on the ultrasound system. The integration and future quantification of new parameters together with on-line review allows new insights into cardiac function, morphology and synchrony that offer great potentials in the evaluation of right and left global and regional function, diagnosis of small areas of ischemia, congenital and valvular heart disease and effects of biventricular pacing in dilated heart asynchrony. This report will review current and future applications of 3-D data acquisition, emphasizing the real-time methods and clinical applications of the new matrix array transducer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A E van den Bosch, B J Krenning, J R T C Roelandt. 2005. Three-dimensional echocardiography.. https://pubmed.ncbi.nlm.nih.gov/16003252/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite-element-method (FEM) model generation of time-resolved 3D echocardiographic geometry data for mitral-valve volumetry.

INTRODUCTION: Mitral Valve (MV) 3D structural data can be easily obtained using standard transesophageal echocardiography (TEE) devices but quantitative pre- and intraoperative volume analysis of the MV is presently not feasible in the cardiac operation room (OR). Finite element method (FEM) modelling is necessary to carry out precise and individual volume analysis and in the future will form the basis for simulation of cardiac interventions. METHOD: With the present retrospective pilot study we describe a method to transfer MV geometric data to 3D Slicer 2 software, an open-source medical visualization and analysis software package. A newly developed software program (ROIExtract) allowed selection of a region-of-interest (ROI) from the TEE data and data transformation for use in 3D Slicer. FEM models for quantitative volumetric studies were generated. RESULTS: ROI selection permitted the visualization and calculations required to create a sequence of volume rendered models of the MV allowing time-based visualization of regional deformation. Quantitation of tissue volume, especially important in myxomatous degeneration can be carried out. Rendered volumes are shown in 3D as well as in time-resolved 4D animations. CONCLUSION: The visualization of the segmented MV may significantly enhance clinical interpretation. This method provides an infrastructure for the study of image guided assessment of clinical findings and surgical planning. For complete pre- and intraoperative 3D MV FEM analysis, three input elements are necessary: 1. time-gated, reality-based structural information, 2. continuous MV pressure and 3. instantaneous tissue elastance. The present process makes the first of these elements available. Volume defect analysis is essential to fully understand functional and geometrical dysfunction of but not limited to the valve. 3D Slicer was used for semi-automatic valve border detection and volume-rendering of clinical 3D echocardiographic data. FEM based models were also calculated. METHOD: A Philips/HP Sonos 5500 ultrasound device stores volume data as time-resolved 4D volume data sets. Data sets for three subjects were used. Since 3D Slicer does not process time-resolved data sets, we employed a standard movie maker to animate the individual time-based models and visualizations. Calculation time and model size were minimized. Pressures were also easily available. We speculate that calculation of instantaneous elastance may be possible using instantaneous pressure values and tissue deformation data derived from the animated FEM.

Echocardiography, Three-Dimensional↗

[New imaging methods in the diagnosis of mitral regurgitation].

Conventional Doppler echocardiographic methods still are limited when being used for evaluation of morphology and function of a regurgitant mitral valve. Methods based on two-dimensional image planes may be insufficient to demonstrate exact spatial localization of pathologic structures due to the need for mental reconstruction of the three-dimensional valve anatomy by the examiner. The determination of severity of mitral regurgitation is based either on the estimation of regurgitation jet size or on geometric assumptions on its shape which often are not correct and reduce the accuracy of the method.New echocardiographic techniques such as 3-D echocardiography provide a comprehensive visualization and assessment of valvular pathomorphology which especially in complex situations will increase sensitivity and diagnostic accuracy when compared to conventional methods. The combination of 3-D echo with three-dimensional Doppler data will allow an even more reliable and precise determination of lesion severity. Other imaging modalities such as magnetic resonance imaging will be a promising alternative due to their three-dimensional data acquisition and the enormous potential for the measurement of intracardiac flow.