PubMed Health⌕ Search

PubMed · 16003675

Break-technique handheld dynamometry: relation between angular velocity and strength measurements.

Abstract

OBJECTIVES: To determine whether the muscle strength, as measured with break-technique handheld dynamometry (HHD), is dependent on the angular velocity achieved during testing and to compare reliability at different angular velocities. DESIGN: Repeated-measures study. Participants underwent HHD by using make-technique (isometric) and break-technique (eccentric) dynamometry at 3 prespecified angular velocities. Elbow movement was recorded with an electrogoniometer. SETTING: Inpatient spinal cord injury unit. PARTICIPANTS: Convenience sample of 20 persons with tetraplegia with weakness of elbow flexors or extensors. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Elbow angular velocity and muscle strength recorded during HHD. RESULTS: With the break technique, angular velocities averaging 15 degrees , 33 degrees , and 55 degrees /s produced 16%, 30%, and 51% greater strength measurements, respectively, than velocities recorded by using the make technique (all P < .006 for comparisons between successive techniques). The intraclass correlation coefficient for intrarater reliability was .89 or greater for all testing techniques. CONCLUSIONS: Greater strength is recorded with faster angular velocities during HHD. Differences in angular velocity may explain the wide range previously reported for break- versus make-technique strength measurements. Variation in angular velocity is a potential source of variability in serial HHD strength measurements, and for this reason the make technique may be preferable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephen P Burns, David E Spanier. 2005. Break-technique handheld dynamometry: relation between angular velocity and strength measurements.. https://doi.org/10.1016/j.apmr.2004.12.041

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗

Percutaneous vertebroplasty and kyphoplasty for the stand-alone augmentation of osteoporosis-induced vertebral compression fractures: present status and future directions.

Enormous research efforts are being expended on two minimally invasive procedures: percutaneous vertebroplasty (VP) and kyphoplasty (KP). The present report, which is a detailed critical review of VP and KP that emphasizes their biomechanics aspects, is divided into six parts. In the first two parts, succinct descriptions are given of osteoporosis-induced vertebral body (VB) compression fractures as the underlying pathology to be treated with VP and KP, the theory of VP and KP, and the techniques used in performing these procedures. Concerns about VP and KP, such as the high radiation exposure burden that may be imposed on both patient and medical personnel and extravasation of the injectable bone cement, are discussed in the third part. Detailed discussions of fourteen issues/questions, such as the extent to which VP or KP affects various biomechanical measures of the augmented VB and those adjacent to it and the appropriate volume of the cement to use, are presented in the fourth part. Ideas for future research, such as development of a new generation of injectable bone cements and identification of an appropriate animal model, are covered in the fifth part. The final section contains a summary of the most salient points/observations made in the report.

Biomechanical Phenomena↗

Effect of oxygen inhibition on composite repair strength over time.

The study was aimed at examining whether an oxygen inhibition layer is required for bonding a repairing to a pre-existing composite, and to determine the time required for free radicals within a composite substrate to decay to the extent that the composite repair strength drops significantly. Ten slabs of Gradia Direct Anterior (GC Corp.) were divided into (1) control group: an interfacial oxygen inhibition layer was created by applying and light-curing two layers of bonding resin (D/E Resin, Bisco) to the slabs surface in atmospheric air; (2) experimental group: the absence of an interfacial oxygen inhibition layer was obtained by light-curing the second bonding resin layer in a nitrogen atmosphere. After 1 and 2 h, 1, 14, and 30 days of air storage, a composite repair was layered over the bonding resin. Microtensile bond strengths were measured and statistically analyzed. The curing atmosphere was not a significant factor for bond strength (p = 0.82), and time and curing atmosphere-time interaction were significant (p < 0.001). The 30 day-strengths were the lowest (p < 0.05). An oxygen-inhibited layer is not initially required for bonding to resin composite, and it takes more than 14 days before the bond strength between a pre-existing and a fresh composite drops.

Biomechanical Phenomena↗