PubMed Health⌕ Search

PubMed · 16007783

Common-path phase-shift interferometry surface plasmon resonance imaging system.

Abstract

Surface plasmon resonance (SPR) and common-path phase-shift interferometry (PSI) techniques are integrated in a biosensing imaging system for measuring the two-dimensional spatial phase variation caused by biomolecular interactions on a sensing chip without the need for additional labeling. The common-path PSI technique has the advantage of long-term stability, even when it is subjected to external disturbances. Hence the system meets the requirements of the real-time kinetic studies involved in biomolecular interaction analysis. The proposed SPR-PSI imaging system demonstrates a detection limit of a 2 x 10(-7) refractive-index change, a long-term phase stability of 2.5 x 10(-4) pi rms for 4 h, and a spatial phase resolution of 10(-3) pi with a lateral resolution of 100 microm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y D Su, S J Chen, T L Yeh. 2005-06-15. Common-path phase-shift interferometry surface plasmon resonance imaging system.. https://doi.org/10.1364/ol.30.001488

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques↗

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques↗

Electrogenerated chemiluminescence of CdSe quantum dots dispersed in aqueous solution.

Electrogenerated chemiluminescence (ECL) of CdSe quantum dots (QDs) dispersed in aqueous solution was studied with bare electrode. The ECL emission was observed at -1.4 V vs. Ag/AgCl and the ECL spectrum peak is similar to that of the defect photoluminescence (PL) spectrum, indicating the surface defects played a critical role in the emission process. The experiment results suggested that dissolved oxygen had a great effect on the ECL intensity. Other influence factors including the electrochemical parameters and QDs concentration were investigated in detail. As an application of the CdSe QDs ECL, the pyrogallol (1, 2, 3-trihydroxybenzene) was detected in aqueous solution. Under the optimal conditions, a linear relationship between ECL intensity and pyrogallol concentration was obtained in the range from 4.0 x 10(-7) to 2.0 x 10(-5) M with a correlation coefficient of 0.9904 and the limit of detection was 6.6 x 10(-8) M (S/N = 3). A possible mechanism about ECL of QDs was also discussed.

Biosensing Techniques↗