PubMed Health⌕ Search

PubMed · 16022013

A laparoscopic method for optimal peritoneal dialysis access.

Abstract

Both medical benefits to the patient and financial incentives to the health care system exist to increase the use of peritoneal dialysis as renal replacement therapy. Providing long-term peritoneal access free of mechanical dysfunction continues to represent a major challenge to the success of this modality. Variable outcomes result from the lack of standard implantation methodology and failure to address persistent problems associated with current implantation techniques. This prospective case study compared noninfectious procedural complications of three approaches to establish peritoneal dialysis access. The groups consisted of 63 catheters implanted by traditional open dissection, 78 catheters implanted by basic laparoscopy without associated interventions, and 200 catheters implanted by advanced laparoscopic methods including rectus sheath tunneling, selective prophylactic omentopexy, and selective adhesiolysis. Mechanical flow obstruction, the major outcome indicator, followed only 1 of 200 (0.5%) implantation procedures in the advanced group and was significantly better (P < 0.0001) than the open dissection (17.5%) and basic laparoscopic (12.5%) groups. A low rate of pericannular leaks (1.3-2%) was not different for the three groups. One pericannular hernia occurred in the open group. Catheter mechanical dysfunction attributable to the surgical technique can nearly be eliminated through adjunctive procedures made possible only by a laparoscopic approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John H Crabtree, Arnold Fishman. 2005. A laparoscopic method for optimal peritoneal dialysis access.. https://doi.org/10.1177/000313480507100209

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The role of surgery in the management of septic shock--extra-abdominal causes of sepsis.

Septic shock is a severe inflammatory response to one or more pathogenic micro-organisms. When a person's immune response is excessively intense, a cascade of phenomena may be activated that ultimately is harmful. Appropriate management of septic shock may include surgical intervention to remove or neutralize the septic focus in an effort to treat the inflammatory response cascade. This is the first of two articles presenting current information on the role of surgery in the management of a patient with septic shock. This article describes extra-abdominal sources of sepsis.

Catheters, Indwelling↗

Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

Catheters, Indwelling↗