Digital position determination system for electron microscopy.

Abstract

The precise determination of object positions within a specimen grid is important for many applications in electron microscopy. For example, real-time position determination is necessary for current statistical approaches and the efficient mapping and relocation of objects. Unfortunately, precise real-time position determination is not available on many older electron microscopes with manual stage controls. This report demonstrates the cost-effective and flexible implementation of a digital position determination system that can be adapted to many hand-operated electron microscopes. A customized solution that includes the hardware and software to accomplish position determination is presented. Lists of required parts, instructions for building the hardware, and descriptions of the developed programs are included. Two LED-photodiode assemblies detect x and y movements via an optical wheel that is in physical contact with the mechanical x and y stage control elements. These detector assemblies are interfaced with an integrated circuit that converts movement information into serial port-compatible signals, which are interpreted by a computer with specialized software. Two electron microscopes, a Philips CM12 (S)TEM and a Philips 201 TEM, were equipped with the described digital position determination system. The position fidelity and position fidelity after reloading of grids were determined for both microscopes. The determined position deviation was 1.06 microm in the x axis and 0.565 microm in the y axis for the Philips CM12 (S)TEM, and 0.303 microm in the x axis and 0.545 microm in the y axis for the Philips 201 TEM. After reloading and computational realigning, the determined average position variation was 2.66 microm in the x axis and 2.61 microm in the y axis for the Philips CM12 (S)TEM, and 1.13 microm in the x axis and 1.27 microm in the y axis for the Philips 201 TEM.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin F Hohmann-Marriott, William P Sharp, Robert W Roberson, Robert E Blankenship. 2005-06-01. Digital position determination system for electron microscopy.. https://doi.org/10.1002/jemt.20196

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Compliance of electronic personal neutron dosemeters with the new International Standard IEC 61526.

The recommendations and test requests for the dose equivalent response of personal neutron dosemeters formulated by the new International Standard IEC 61526 are summarised. In particular, IEC 61526 allows the use of broad fields if dosemeters do not fulfil the hard requirements using monoenergetic neutrons. Some broad fields which can work as a replacement field using ISO sources (252Cf, 252Cf (D2O mod.), 241Am-Be) and simulated workplace fields (CANEL and SIGMA) are described. This work shows the results of recent measurements of the personal dose equivalent response for the dosemeters Thermo Electron EPD-N2, Aloka PDM-313 and the prototype dosemeter PTB DOS-2002, and discusses their compliance with respect to the new IEC 61526 standard.

Electronics↗

Treatment of waste printed wire boards in electronic waste for safe disposal.

The printed wire boards (PWBs) in electronic waste (E-waste) have been found to contain large amounts of toxic substances. Studies have concluded that the waste PWBs are hazardous wastes because they fails the toxicity characteristic leaching procedure (TCLP) test with high level of lead (Pb) leaching out. In this study, two treatment methods - high-pressure compaction and cement solidification - were explored for rendering the PWBs into non-hazardous forms so that they may be safely disposed or used. The high-pressure compaction method could turn the PWBs into high-density compacts with significant volume reduction, but the impact resistance of the compacts was too low to keep them intact in the environment for a long run. In contrast, the cement solidification could turn the PWBs into strong monoliths with high impact resistance and relatively high compressive strength. The leaching of the toxic heavy metal Pb from the solidified samples was evaluated by both a dynamic leaching test and the TCLP test. The dynamic leaching results revealed that Pb could be effectively confined in the solidified products under very harsh environmental conditions. The TCLP test results showed that the leaching level of Pb was far below the regulatory level of 5mg/L, suggesting that the solidified PWBs are no longer hazardous. It was concluded that the cement solidification is an effective way to render the waste PWBs into environmentally benign forms so that they can be disposed of as ordinary solid wastes or beneficially used in the place of concrete in some applications.

Electronics↗

Evaluation of dose equivalent by the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities.

This paper presents the results of measurements made with the electronic personal neutron Saphydose-N during the four campaigns of the European contract EVIDOS (EValuation of Individual DOSimetry in mixed neutron and photon radiation fields). These measurements were performed at Institute for Radiological Protection and Nuclear Safety (IRSN) in France (C0), at the Krümmel Nuclear Power Plant in Germany (C1), at the VENUS Research Reactor and the Belgonucléaire fuel processing plant in Belgium (C2) and at the Ringhals Nuclear Power Plant in Sweden (C3). The results for Saphydose-N are compared with reference values for dose equivalent.

Electronics↗