PubMed Health⌕ Search

PubMed · 16046972

Compatibility of mechanical and computerized axiographs: a pilot study.

Abstract

STATEMENT OF PROBLEM: There is little known information comparing axiographic data obtained with a mechanical device and data obtained with a computerized device. However, long-term follow-up of patients may necessitate comparison of previously made mechanical axiographic data with records obtained through computer-aided axiography. PURPOSE: The purpose of this study was to compare measurements between mechanical and computerized axiographs in recording the rotational and translation movements of the mandible. MATERIAL AND METHODS: The study enrolled 31 subjects with no detectable clinical signs of temporomandibular disorders. A single operator obtained 3 separate axiographic tracings of right and left condylar paths for each subject, using repeated opening, closing, protrusive, and retrusive movements. Data were collected for both the mechanical (SAM Axiograph Axo 200), and the computerized axiographs (SAM Axiotron and Axo 500). Angular (degrees) and linear measurements (mm) for the mechanical axiograph were made from the tracings obtained on grid paper using a compass, ruler, and protractor. The computer performed the measurements for the computerized axiograph tracings. All parameters were compared statistically with a Wilcoxon signed rank test (alpha = .05). The same operator remeasured all mechanical axiographic tracings for 20 subjects 1 week later to evaluate measurement error. Chronbach's alpha was used as a measure of consistency between the 2 measurements. RESULTS: Mean opening and closing angles varied between 52.4 and 54.2 degrees, and mean protrusive, and retrusive angles varied between 50.1 and 54.9 degrees. Mean opening and closing distances varied between 11.4 and 12.3 mm, and mean protrusive and retrusive distances varied between 8.2 and 8.7 mm. Comparison with the Wilcoxon signed rank test showed no significant differences for any parameter tested. There were high and medium inter-item correlations between repeated measurements of the manual device when Chronbach's alpha was applied, but these results were not sufficient to prove consistency between 2 consecutive measurements. CONCLUSION: The results showed nonsignificant differences between the recordings of the mechanical and computerized axiographs tested. The authors hypothesize that minor differences may be attributed to hand-measuring errors for the tracings generated by the mechanical axiograph. This study is limited due to the impact of poor precision of the manual device on the study results when these recordings are compared to another instrument. Therefore, it is not possible to conclude that data from the manual and the computerized axiographs are compatible with each other.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Kucukkeles, H Ozkan, A Ari-Demirkaya, A M Cilingirturk. 2005. Compatibility of mechanical and computerized axiographs: a pilot study.. https://doi.org/10.1016/j.prosdent.2005.04.025

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Blinatumomab for Replacing Chemotherapy in Pediatric Acute Lymphoblastic Leukemia.

BACKGROUND: Blinatumomab, a bispecific T-cell engager targeting the CD19 antigen on B cells, may offer an option to safely replace cycles of traditional chemotherapy in pediatric patients with newly diagnosed high-risk B-cell acute lymphoblastic leukemia (ALL). METHODS: We randomly assigned, in a 1:1 ratio, children with high-risk B-cell ALL to receive two cycles of blinatumomab (blinatumomab group) or two cycles of chemotherapy (control group) after consolidation. The primary end point was event-free survival as evaluated in a time-to-event analysis; the duration of event-free survival was defined as the time from randomization to the first event among resistance to protocol treatment, relapse, second cancer, or death from any cause. Our primary objective was to evaluate whether the 4-year event-free survival would be 10 percentage points higher in the blinatumomab group than in the control group. RESULTS: Overall, 709 of 768 eligible patients (92.3%) underwent randomization; 358 were assigned to the blinatumomab group and 351 to the control group. A planned interim analysis at a median follow-up of 2.9 years showed an estimated 4-year event-free survival of 83.0% (95% confidence interval [CI], 77.4 to 87.4) in the blinatumomab group and 70.3% (95% CI, 63.8 to 75.9) in the control group (P&#x2009;=&#x2009;0.0002 in an intention-to-treat analysis). The estimated hazard ratio for a primary end-point event (blinatumomab vs. control) was 0.51 (95% CI, 0.35 to 0.73) as assessed with a Cox model. Infection related to the trial treatment occurred in 23.9% of patients in the blinatumomab group and in 69.4% of those in the control group (P<0.001). Life-threatening adverse events occurred in 2 patients (0.5%) in the blinatumomab group, including one (in 0.3%) that was fatal, and in 16 patients (4.7%) in the control group. Neurotoxic events were reported in 12.0% and 3.2%, respectively (P<0.001). Cytokine release syndrome of grade 2 or higher occurred in 1.1% of patients in the blinatumomab group. CONCLUSIONS: In children with newly diagnosed high-risk B-cell ALL, replacement of two cycles of highly toxic conventional chemotherapy with blinatumomab resulted in a significantly greater percentage of patients with event-free survival at 4 years. (Funded by Deutsche Krebshilfe and others; AIEOP-BFM ALL 2017 EudraCT number, 2016-001935-12; EU Clinical Trials number, 2023-509856-32-00; and ClinicalTrials.gov number, NCT03643276.).

Adolescent↗

Association between plasma homocysteine levels and P-wave dispersion in pediatric patients with hyperhomocysteinemia.

UNLABELLED: Hyperhomocysteinemia has been recognized as a cardiovascular risk factor associated with endothelial dysfunction, oxidative stress, and vascular inflammation. Experimental and clinical studies suggest that elevated homocysteine levels may also influence myocardial electrophysiology and contribute to arrhythmogenesis. However, data regarding the relationship between homocysteine levels and electrocardiographic markers of atrial conduction in pediatric populations remain limited. This study aimed to evaluate the association between plasma homocysteine levels and electrocardiographic parameters, particularly P-wave dispersion, in children. This multicenter retrospective case-control study included pediatric patients evaluated in four tertiary pediatric metabolism centers between January 2023 and December 2025. A total of 47 patients with hyperhomocysteinemia (plasma total homocysteine&#x2009;&#x2265;&#x2009;15&#xa0;&#xb5;mol/L) and 43 age- and sex-matched controls with normal homocysteine levels were included. Controls were selected from the screened population among children with available homocysteine measurements, electrocardiographic and echocardiographic evaluations, and no confirmed inherited metabolic disease or cardiac disorder. Clinical, biochemical, and electrocardiographic parameters, including maximum P-wave duration and P-wave dispersion, were retrospectively analyzed. A total of 90 participants were included, comprising 47 children with hyperhomocysteinemia and 43 healthy controls. P-wave dispersion and maximum P-wave duration were significantly higher in the hyperhomocysteinemia group compared with controls (48.96 [19.48-100.0] vs. 38.57 [10.57-71.19] ms, p&#x2009;<&#x2009;0.001). Plasma homocysteine levels showed a moderate positive correlation with P-wave dispersion (&#x3c1;&#x2009;=&#x2009;0.441, p&#x2009;<&#x2009;0.001). These differences were more pronounced in children with higher homocysteine levels and in younger age groups (<&#x2009;2&#xa0;years and 2-14&#xa0;years). In contrast, PR interval (p&#x2009;=&#x2009;0.790) and QTc interval (p&#x2009;=&#x2009;0.183) did not differ significantly between groups. Vitamin B12 levels were significantly lower in the hyperhomocysteinemia group (p&#x2009;=&#x2009;0.013), while folate levels were comparable (p&#x2009;=&#x2009;0.974). Although sodium, potassium, and magnesium levels differed significantly between groups, all values remained within normal physiological ranges. CONCLUSIONS: Children with hyperhomocysteinemia showed increased P-wave dispersion compared with controls. These findings suggest an association between elevated homocysteine levels and altered atrial conduction parameters in children. Further prospective studies are needed to determine the clinical significance of these findings. WHAT IS KNOWN: &#x2022; Hyperhomocysteinemia is associated with cardiovascular risk and endothelial dysfunction. &#x2022; Elevated homocysteine levels have been linked to cardiac electrophysiological alterations in adult populations. WHAT IS NEW: &#x2022; Elevated homocysteine levels are associated with increased P-wave dispersion in children, with more pronounced effects observed in younger age groups. &#x2022; These findings support an association between hyperhomocysteinemia and altered atrial conduction parameters in children.

Adolescent↗

Characteristics of post-exercise responders versus non-responders following aerobic or isometric exercise in physically inactive adults of African and South Asian descent with high-normal blood pressure or grade I hypertension.

OBJECTIVE: To investigate interindividual variability in post-exercise hypotension (PEH) and to characterise cardiovascular and autonomic differences between responders and non-responders following aerobic and isometric exercise in adults of African and South Asian descent with elevated blood pressure (BP). METHODS: Physically inactive adults of African and South Asian descent living in Suriname (18-65&#x2009;years) with high-normal BP or grade I hypertension participated in a randomised controlled crossover trial. In this randomised cross-over trial, 47 adults (50.1&#x2009;&#xb1;&#x2009;10.8&#x2009;years; 38% male) with high-normal blood pressure or grade I hypertension completed three conditions: aerobic exercise (30&#x2009;min at 40-60% heart rate reserve), isometric handgrip exercise, and a non-exercise control. Ambulatory BP was assessed over 24&#x2009;h. PEH was defined as the net effect: (post-exercise&#x2009;-&#x2009;pre-exercise) - (post-control&#x2009;-&#x2009;pre-control). Participants were classified as responders if daytime BP decreased &#x2265;5&#x2009;mmHg. Arterial stiffness, cardiac, and autonomic parameters were assessed. RESULTS: Following aerobic exercise, 46% of participants were classified as systolic responders compared with 28% after isometric exercise. No baseline differences were observed in demographic or clinical characteristics between responders and non-responders, suggesting that PEH variability may reflect underlying physiological rather than clinical differences. Aerobic responders demonstrated greater reductions in aortic augmentation index (-19.4% vs. -10.9%, p&#x2009;=&#x2009;0.05), larger increases in stroke volume (+8.1 vs. -5.3&#x2009;mL, p&#x2009;=&#x2009;0.05) and cardiac output (+1.54&#x2009;&#xb1;&#x2009;1.89 vs. +0.58&#x2009;&#xb1;&#x2009;1.60&#x2009;L/min, p&#x2009;=&#x2009;0.009), and more favourable autonomic recovery. Among all variables, only the change in cardiac output was associated with PEH magnitude (r&#x2009;=&#x2009;-0.46, p&#x2009;=&#x2009;0.006). No consistent physiological differences were observed following isometric exercise. CONCLUSION: PEH following aerobic exercise is characterised by a distinct responder phenotype associated with greater reductions in aortic augmentation index and favourable cardiac adaptations. These findings highlight substantial interindividual variability in BP responses and support the need for individualised exercise strategies in hypertension management.

Adolescent↗