Reducing respirator fit test errors: a multi-donning approach.

Abstract

As a continuation of recent studies to assess the accuracy of existing fit test methods, a multi-donning approach to fit testing is presented. As an example of that approach, a multi-donning quantitative fit test for filtering-facepiece respirators is presented and analyzed by comparing its error rates with those of the single-donning approach of current fit test methods. That analysis indicates the multi-donning fit test has the potential to reduce both the alpha error and the beta error to half that of single-donning fit tests. The alpha error is the error of failing a respirator that should pass; the beta error is the error of passing a respirator that should fail. Lowering fit test error rates for filtering-facepiece respirators is important because fit testing is an essential means of helping assure that an individual has selected an adequately fitting respirator. To reduce the alpha and beta error inherent in current fit test methods, the proposed fit test for filtering-facepiece respirators incorporates five donnings of the facepiece, unlike the single donning of existing fit test methods. The analysis presented here indicates that the multiple-donning approach reduces the element of chance in the fit test result and thereby increases the consistency and accuracy of the fit tests. The time to conduct the multi-donning test can approximate the time for current, single-donning tests by shortening the time the respirator is worn after each donning to about 10 sec. And, unlike current fit tests for filtering-facepieces that measure only faceseal leakage, the example multiple-donning fit test considered here is based on a measurement of total leakage (faceseal plus filter). Utilizing total respirator leakage can result in simpler quantitative fit test instrumentation and a fit test that is more relevant to the workplace. Further trials with human subjects are recommended in order to validate the proposed multi-donning approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D L Campbell, C C Coffey, P A Jensen, Z Zhuang. 2005. Reducing respirator fit test errors: a multi-donning approach.. https://doi.org/10.1080/15459620500182174

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Calibration of spectra from dispersive XAS beamlines.

The DXAS Calibration computer program provides a quantitative and automated solution to the problem of calibrating spectra from dispersive XAS beamlines. Such spectra, obtained in arbitrary energy units, are calibrated with respect to the absorption features of a supplied reference spectrum, which has been obtained under similar conditions on a calibrated beamline. In addition to basic energy coordinate transformation parameters, DXAS Calibration supplies instrument corrections to compensate for mismatches in instrument response functions between the dispersive and reference beamlines.

Equipment Failure Analysis↗

Measuring orthopedic implant wear on standard radiographs with a precision in the 10 microm-range.

The aim of this study has been to explore and verify whether the use of a previously designed Analysis-by-Synthesis algorithm is capable to precisely measuring implant wear. The abrasion of polyethylene particles is seen as the main reason for the loosening of prosthetic components in the hip. It lies in the sub-millimeter range, and precision is a crucial point in wear measurement. In the Analysis-by-Synthesis algorithm, the synthetic X-ray image of the implant is matched to its original X-ray projection. This intensity based approach and the use of X-ray images with their inherent high resolution allow principally precise measurements. Wear has been defined based on the estimated implant parameters and under minimization of the impact of the main sources of error. The latter was theoretically studied in a sensitivity analysis. The use of the algorithm was tested in vitro as well as in vivo. In experimental data, the accuracy and the impact of the pelvic position and orientation were studied. The precision was assessed using dual radiographs of 20 patients with total hip replacement. A standard deviation of 49 microm was found.

Equipment Failure Analysis↗

Behavior of metal implants used in ENT surgery in 7 Tesla magnetic resonance imaging.

Magnetic resonance imaging (MRI) has become increasingly important as an imaging technique in cross-sectional imaging of head and neck diseases. To investigate whether MRI examinations can be performed without risk in patients with metal implants even at higher field strengths, we examined different materials in 7 Tesla MRI. Implants near sensory organs like the middle ear or eye are of particular interest here. Using the 7 Tesla research MRI for small animals, we tested implants made of various metals like titanium, gold, gold/platinum, platinum/iridium, gold-plated silver, PTFE and stainless steel for heating, translocation and rotation according to a standardized protocol. A fiber optic temperature probe measured the heating of the implant before, during and after MRI scanning. None of the implants showed significant heating. The gold-plated stainless steel ventilation tube was the only implant to markedly change its position already in the Petri dish. Of the remaining implants, a trachea support ring, a nose dilatator and the wire from the ventilation tubes moved during vibration of the Petri dish. With exception of two implants, all implants changed positions in the water bath. In the swim test, the gold implants showed the least movement of all the implants. In this study, the properties of the non-ferromagnetic implant materials differed in the 7 Tesla MRI. Stainless steel ventilation tubes, the trachea support ring and the nose dilatator were not suited for the 7 Tesla MRI system, because they changed their position during MRI. In the case of ventilation tubes with a steel wire, the wire should be removed before MRI to prevent injury to the external auditory canal. There was a tendency for the pure gold implants to move less in the 7 Tesla MRI than all other tested materials. General statements cannot be made about the MRI suitability of different implants. Every implant should be individually examined to confirm its definitive MRI compatibility. Particularly, middle ear implants warrant special attention here due to their closeness to the oval window.

Equipment Failure Analysis↗