PubMed Health⌕ Search

PubMed · 16086300

Simultaneous spin-echo refocusing.

Abstract

A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminates this potential source of artifacts without spoiling the correctly timed stimulated echoes, which, similar to RARE (TSE) sequences, add coherently to the primary echoes. Comparisons show equivalent artifact elimination using phase cycling, periodic spoiling, and a previously developed spoiling scheme for non-Carr-Purcell-Meiboom-Gill sequences. A comparison of head images at 1.5 T acquired with SER-TSE and conventional TSE T1-weighted sequences show no degradation in image quality nor SNR. T2-weighted imaging is not achievable with the current implementation, but possible solutions are proposed. The proposed technique might prove especially beneficial at higher field strengths, where the reduced number of refocusing pulses for multislice SER-TSE decreases RF power deposition. SER spin-echo imaging offers an approach that is very different from low flip angle imaging to mitigate RF heating limitations in high-field clinical imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Matthias Günther, David A Feinberg. 2005. Simultaneous spin-echo refocusing.. https://doi.org/10.1002/mrm.20587

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗