PURPOSE OF REVIEW: Endoscopic confocal microscopy is a new endoscopic imaging technology that produces high-magnification cross-sectional images of the gastrointestinal epithelium during endoscopy. These high-magnification images might allow the endoscopist to make a tissue diagnosis during endoscopy without biopsy and histopathology. The purpose of this article is to review the salient features of endoscopic confocal microscopy, describe current clinical research areas using the technology, and depict its potential role in the management of gastrointestinal diseases. This review includes an overview of the technology, a review of recent publications describing its function, and a discussion of potential applications. RECENT FINDINGS: Endoscopic confocal microscopy has been technologically feasible only for a short time; therefore, the published experience is limited. Studies describing the use of endoscopic confocal microscopy for the detection of dysplastic tissue have been limited to a single paper in which endoscopic confocal microscopy was reported to be highly sensitive and specific for the detection of colonic dysplasia in a general screening population. Active areas of investigation include detecting dysplasia in ulcerative colitis and Barrett's esophagus. A recent case report detailed the ability of endoscopic confocal microscopy to detect gastric Helicobacter pylori in vivo. SUMMARY: Endoscopic confocal microscopy is a new imaging technology that produces high-magnification cross-sectional images of the gastrointestinal tract. Its role in detecting and managing diseases of the gastrointestinal tract has been studied in colon cancer screening and is currently being evaluated in a variety of premalignant conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John A Evans, Norman S Nishioka. 2005. Endoscopic confocal microscopy.. https://doi.org/10.1097/01.mog.0000174217.62214.10

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

PillCam ESO in esophageal studies: improved diagnostic yield of 14 frames per second (fps) compared with 4 fps.

BACKGROUND AND STUDY AIM: Capsule endoscopy, using the PillCam ESO and sending images at a rate of 4 frames per second (fps), has a high sensitivity and specificity in diagnosing gastroesophageal reflux disease (GERD) lesions. We tested a new device which produces images at a rate of 14 fps. The diagnostic performance and esophageal visualization of these two devices were compared. PATIENTS AND METHODS: 42 patients with GERD symptoms and eight patients with a history of Barrett's esophagus had an esophagogastroduodenoscopy (EGD). All patients underwent capsule endoscopy of the esophagus within 1 hour prior to EGD. The first 25 patients had a capsule endoscopy examination with the 4-fps device. The following 25 patients underwent capsule endoscopy under identical conditions but using the 14-fps device. The reader of the capsule endoscopy study was blinded to the EGD findings. A diagnosis of GERD or Barrett's esophagus was established with EGD. The findings at capsule endoscopy were compared with the EGD findings. We also examined how frequently the esophagus in its entirety was visualized by these two devices. RESULTS: The 4-fps device diagnosed 16/19 cases of esophageal erosions or ulcers (sensitivity 84 %) and 6/8 cases of Barrett's esophagus (sensitivity 75 %). The 14-fps capsule diagnosed 16/16 cases of esophageal ulcers or erosions and 7/7 cases of Barrett's esophagus (sensitivity 100 %). The total diagnostic miss rate in the 4-fps group was 5/27 (18 %) whereas the diagnostic miss rate in the 14-fps group was 0/23 (0 %) P < 0.02). The upper esophageal sphincter (UES) was clearly identified in 6/25 patients (24 %) in the 4-fps group and in 20/25 patients (80 %) in the 14-fps group ( P < 0.01). The entire esophagus was well visualized in 3/25 patients (12 %) by the 4-fps device and in 19/25 (76 %) by the 14-fps device ( P < 0.01). The superiority of the 14-fps PillCam ESO capsule is consistent with the data obtained from fluoroscopic studies of swallowed PillCam capsules, showing that capsule speed may reach 20 cm/s. For the 14-fps PillCam this means one image transmitted per 3-cm segment at maximal capsule speed, therefore still allowing for full visualization of the entire esophagus. CONCLUSIONS: Capsule endoscopy using the 14-fps PillCam ESO showed a greater sensitivity than that of the 4-fps device for identifying GERD. The 14-fps PillCam ESO was statistically superior to the 4-fps device in visualizing the opening of the UES and the entirety of the esophagus.

Endoscopes, Gastrointestinal↗

The accuracy of PillCam ESO capsule endoscopy versus conventional upper endoscopy for the diagnosis of esophageal varices: a prospective three-center pilot study.

BACKGROUND AND STUDY AIMS: Variceal bleeding is a major complication of cirrhosis, and is associated with a 20 % mortality at 6 weeks. Current international guidelines recommend that patients with cirrhosis are screened by conventional upper endoscopy (esophagogastroduodenoscopy, EGD) in order to detect esophageal varices. The recently developed PillCam ESO esophageal capsule endoscope has been shown to be an accurate diagnostic tool in the investigation of patients with gastroesophageal reflux and Barrett's esophagus. We compared the PillCam ESO capsule endoscope with EGD for the detection of esophagogastric varices and portal hypertensive gastropathy in patients with cirrhosis. PATIENTS AND METHODS: A pilot trial was conducted at three sites. Patients with cirrhosis who were undergoing clinically indicated EGD for screening or surveillance for esophageal varices underwent a PillCam ESO study followed by an EGD within 48 hours. Capsule videos were assessed by an investigator who was blinded to the patient's medical history and EGD findings. RESULTS: A total of 23 of the 32 enrolled patients were found to have esophageal varices at both EGD and PillCam ESO endoscopy. In one patient PillCam ESO detected small varices that were not seen at EGD. The overall concordance between PillCam ESO and EGD was 96.9 % for the diagnosis of esophageal varices and 90.6 % for the diagnosis of portal hypertensive gastropathy. There were no adverse events related to PillCam ESO endoscopy. CONCLUSIONS: In a high-prevalence population, PillCam ESO may represent an accurate noninvasive alternative to EGD for the detection of esophageal varices and portal hypertensive gastropathy. A large-scale trial is underway to validate and expand these findings.

Endoscopes, Gastrointestinal↗

Clinical utility of wireless capsule endoscopy: experience with 200 cases.

GOALS: To evaluate the indications and diagnoses made with 200 small bowel capsule endoscopies in an academic medical center. BACKGROUND: Wireless capsule endoscopy (PillCam SB) has recently become available as a new tool in the evaluation of patients with small bowel diseases. Its impact on patient care and usefulness in clinical practice has steadily been gaining ground, yet there are few studies that evaluate large numbers of patients. METHODS: A retrospective review of wireless capsule endoscopies was performed between September 2003 and January 2005. Reviewed are the indications for the studies, number of complete and incomplete examinations, evaluation of gastric and small bowel transit times, findings made on examination, and the percent of diagnoses made and diagnoses suspected for each study indication. RESULTS: A total of 200 cases were reviewed. Indications included anemia (66% of cases), gastrointestinal hemorrhage (31% cases), abdominal pain (21% cases), diarrhea (11% cases), and other indications such as evaluation of abnormal radiographic findings or surveillance of inflammatory bowel disease (9% cases). The average patient age was 61.5 years (SD +/- 19.1 years). Males comprised 49% of patients. The wireless capsule endoscopy study completely evaluated the entire small bowel in 87% of cases. The most common cause for an incomplete examination was premature battery failure in 8% of cases. Only 9.5% of studies were normal without findings. Small bowel ulcerations were present in 38% of studies. Vascular ectasias were present in 23% of studies. Overall, a diagnosis was made in 23% of all studies, whereas a diagnosis was suspected based on the findings in an additional 31% of studies. The indication with the highest percentage of diagnoses made or suspected was gastrointestinal hemorrhage, with a diagnostic yield of 65%, followed by anemia 61%, diarrhea 36%, and pain 17%. CONCLUSIONS: Wireless capsule endoscopy is a valuable diagnostic tool in the evaluation of occult small bowel lesions, and was most effective in patients with gastrointestinal hemorrhage and anemia.

Endoscopes, Gastrointestinal↗