Occult glove perforations: frequency during interventional radiologic procedures.

Abstract

Because the intact surgical glove is an important barrier against exposure to blood and other body fluids, occult glove perforations occurring during procedures may have implications for infection control and protection of health care workers. Although the frequency of occult glove perforations during surgery has been studied, no such data have been reported for interventional radiology. This study was designed to determine the frequency of occult glove perforations in interventional radiology. Gloves used during interventional radiologic procedures were collected and tested for occult perforations according to previously accepted methods. The frequency of occult defects in unused gloves was also determined. A form completed for each pair of gloves indicated length of use, awareness of perforations, and information about the procedure. The anatomic distribution of perforations was also studied. Occult perforations were found in 49 (10%) of 492 used gloves. The frequency of defects in unused gloves was 1% (2/160). Gloves worn fewer than 2 hr had a perforation rate of 7% (29/406), and those worn 2 hr or longer had a rate of 23% (20/86; p less than .0001). Perforations were noticed by the wearer in only three (6%) of the 49 perforations. The perforation rate for inner gloves of a double-glove set was 3% (1/34; the corresponding outer glove also was perforated). Although the 10% rate of occult glove perforation during interventional radiologic procedures found in this series is lower than rates described with surgical procedures, it is not insignificant. The significant increase in the rate of perforation when gloves are worn more than 2 hr suggests that gloves should routinely be changed at or before 2 hr of wear, particularly in procedures involving high-risk patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M E Hansen, D D McIntire, G L Miller. 1992. Occult glove perforations: frequency during interventional radiologic procedures.. https://doi.org/10.2214/ajr.159.1.1609687

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗