PubMed Health⌕ Search

PubMed · 16104700

A colorimetric sensor array for organics in water.

Abstract

Molecular recognition of organic compounds in aqueous solutions is inherently challenging due to the potential interference from the very high concentration of water. Here we present a simple colorimetric sensor array that probes a wide range of chemical properties. By printing hydrophobic dyes on a hydrophobic membrane, sensor arrays are easily prepared that provide substantial chemical selectivity for the identification and quantification of various organics (both single compounds and complex mixtures) dissolved in water. It is possible to differentiate easily even among closely related organic compounds. Upon immersion in aqueous solutions, digital imaging of the dye array before and after exposure to an analyte provide a color change profile that is a fingerprint for the organic components of the solution. Facile identification of a wide variety of aqueous organic solutions is possible over a concentration range of 0.1 M to 1 muM. Complex mixtures present no inherent difficulty; for example, a series of commercial soft drinks were easily distinguished using the colorimetric sensor array approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chen Zhang, Kenneth S Suslick. 2005-08-24. A colorimetric sensor array for organics in water.. https://doi.org/10.1021/ja052606z

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Selective and sensitive colorimetric sensing of carbosulfan based on BiO2-x/Bi2O2.75 nanosheets with excellent haloperoxidase-like activity.

The development of colorimetric methods based on directly inhibiting nanozyme activity for pesticide detection has attracted considerable attention. In this study, we report a novel colorimetric sensing strategy utilizing BiO2-x/Bi2O2.75 nanosheets (BiO2-x/Bi2O2.75 NSs) with haloperoxidase (HPO)-like activity for the rapid and sensitive detection of carbosulfan (CBS) in foods. Oxygen-vacancy-rich BiO2-x/Bi2O2.75 NSs with HPO-like activity were rationally constructed. Kinetic studies revealed a remarkable Michaelis-Menten constant (Km) of 0.014 mM for I-, indicating a higher affinity for iodide ions than other reported HPO-like nanozymes, as evidenced by its lower Km. Under acidic conditions, CBS tends to be hydrolyzed to produce reductive sulfide species, which directly inhibit the iodoperoxidase-like activity of BiO2-x/Bi2O2.75 NSs, enabling selective detection with a limit of detection (LOD) of 0.18 μg/mL and a linear range of 0.20-100 μg/mL. When the concentration of interfering pesticides and substances was 5 times that of CBS, the sensor remained unaffected, exhibiting excellent stability and specificity. This work contributes to the detection of CBS in complex food matrices, bridging the application gap of HPO-like nanozymes in pesticide detection and providing a promising method for food safety detection.

Colorimetry↗

Modification of the Stewart biphasic colorimetric assay for stable and accurate quantitative determination of Pluronic and Tetronic block copolymers for application in biological systems.

Block copolymers are increasingly being applied in areas such as transfection, membrane sealing, site-specific targeting, and bionanoengineering yet there is a relative paucity of assays available for simple, stable and reproducible colorimetric determination of copolymer concentration in solution. We have focused on improving the accuracy and reproducibility of a modified version of the Stewart biphasic colorimetric assay for quantitative determination of Pluronic (poloxamer) and Tetronic (poloxamine) macromolecules. The optimized assay achieved linear response ranges in chloroform for commonly used copolymers such as poloxamine 904 (20-300 microg/ml), poloxamine 908 (10-400 microg/ml), poloxamer 402 (20-400 microg/ml), and poloxamer 407 (10-400 microg/ml). Variation in the type of chlorinated solvent used significantly increased assay sensitivity, presumably through macromolecular reorientation, affording increased access for copolymer-ferrothiocyanate complexation. This was found to be optimally favored by the planar geometry of the solvent cis 1,2-dichloroethylene. For application to biological systems copolymer-protein interactions were for the first time determined and were found to be dependent on the fraction of hydrophobic constituents of the block copolymers and protein type. For instance serum albumin was found to interact with copolymers of low hydrophilic-lipophilic balance values and poly(propylene oxide) contaminants, whereas this interaction was not significant with the relatively hydrophilic IgG. In such systems the colorimetric assay directly determines the fraction of unbound (free) copolymer in the presence of proteins.

Colorimetry↗