PubMed Health⌕ Search

PubMed · 16114649

Engineering evolves to meet challenges.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Luis Burnay. 2005. Engineering evolves to meet challenges.. https://pubmed.ncbi.nlm.nih.gov/16114649/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cyclodextrins micrometric powders obtained by supercritical fluid processing.

Supercritical fluid technology offers the possibility to produce dry powder formulations of biocompatible materials, overcoming the drawbacks of classical micronization processes. In this work, Supercritical Assisted Atomization (SAA) has been used to micronize alpha-cyclodextrin (alpha-CD) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD). Some process parameters, such as precipitation temperature and solute concentration in the liquid solution, have been studied to evaluate their influence on morphology and size of precipitated particles. Cyclodextrins (CDs) micronization has been successful: well-defined spherical microparticles of alpha-CD and HP-beta-CD have been produced. Particle size analysis revealed that sharp distributions have been obtained: 95% of particles have diameters ranging between 0.1 and 5 microm for both CDs. X-ray and DSC analyses have been also performed to investigate CDs modifications induced by SAA processing: amorphous particles have been obtained in both cases, whereas raw alpha-CD was crystalline and raw HP-beta-CD was amorphous.

Automation↗

Determination of a prostaglandin D2 antagonist and its acyl glucuronide metabolite in human plasma by high performance liquid chromatography with tandem mass spectrometric detection--a lack of MS/MS selectivity between a glucuronide conjugate and a phase I metabolite.

A method for the determination of a prostaglandin D(2) receptor antagonist (I, a compound being evaluated for the prevention of niacin induced flushing) and its acyl glucuronide metabolite (II) in human plasma is presented. The method utilized high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection using an atmospheric pressure chemical ionization (APCI) interface operated in the positive ionization mode. The product ion was a radical cation generated via a homolytic bond cleavage. A chemical analog of the drug was used as internal standard (III). The acyl glucuronide metabolite (II) was detected using the same precursor-to-product ion transition used for the parent compound after chromatographic separation of I and II. Drug and metabolite were extracted using semi-automated, 96-well format solid phase extraction (SPE), and chromatography was performed using a reverse phase analytical column with an isocratic mobile phase. The chromatographic retention factor (k') of II was found to be highly sensitive to mobile phase formic acid concentration. An adjustment in mobile phase formic acid concentration improved the chromatographic separation between II and a mono-hydroxylated metabolite after an unexpected lack of MS/MS selectivity between the two molecules was observed. The dependence of retention factor on formic acid concentration (k' increased as formic acid concentration decreased) was thought to indicate polar interactions between II and the stationary phase. The stability of II in spiked human plasma was determined. The rate of hydrolysis back to parent compound was relatively low (approximately 0.1 and 0.5% per hour at room temperature and 4 degrees C, respectively) indicating that significant changes in analyte concentrations did not occur during sample processing. The concentration range of the assay was 10-2500 ng/mL for both drug and glucuronide metabolite.

Automation↗

Analytical performance of the Iris iQ200 automated urine microscopy analyzer.

BACKGROUND: We evaluated the Iris iQ200 Automated Urine Microscopy Analyzer to find out if the instrument performed better than traditional visual bright field microscopy in detecting basic urine particles, as assessed against reference phase contrast microscopy. METHODS: The HUSLAB quality system was followed in planning and completing the evaluation process. The iQ200 instrument results from 167 mid-stream, uncentrifuged urine specimens were compared to those obtained with phase contrast reference microscopy, and to those with routine bright field microscopy. Linearity, carry-over and precision were tested according to well-established protocols. RESULTS: The iQ200 counted erythrocytes (RBC) at r=0.894 (R(2)=0.799) with Automated Particle Recognition (APR) software alone and at r=0.948 (R(2)=0.898) after re-classification. The performance for leukocytes (WBC) was r=0.885 with APR and r=0.978 after re-classification. The correlations of counting after user re-classification were r=0.927 for squamous epithelial cells (SQEP), r=0.856 for casts, and r=0.706 for non-squamous epithelial cells. The iQ200 showed good linearity and precision and no carry-over was detected. CONCLUSIONS: The Iris iQ200 was capable to count reliably RBC, WBC, and SQEP cells and to identify a fraction of bacteria and renal elements. Counting results equalled or exceeded that of routine bright field microscopy or earlier flow cytometric technology. The instrument eliminates manual sample preparation but requires a well-trained technologist for re-grouping of findings.

Automation↗