[Scaphoid percutaneous osteosynthesis by screw using computer assisted surgery: an experimental study].

Abstract

Scaphoid fractures are sometimes difficult to diagnose and even more difficult to fix. Recent progress such as miniaturization of osteosynthesis material, adoption of the percutaneous route, and widening of the indications to include undisplaced fractures has still not abolished complications. In this context, computer assisted surgery (CAS) may be useful and deserves further study. To apply it to the scaphoid, it is initially necessary to immobilize the "wrist hand fingers" unit in a device adapted to make it a rigid unit. It is then necessary to choose the correct configuration of CAS system. The pedicular fluoroscopic navigation system, which is apparently similar to scaphoid screw insertion, was chosen for this study. The goal of this study is to define the osteosynthesis bases of the scaphoid with CAS. A fresh anatomical subject divided at the elbow joint was prepared at the DETERCA laboratory of the university Bordeaux 2. The solid "wrist hand fingers" unit was immobilized in extension and ulnar deviation of the wrist by a malleable, stable and radio transparent device. The first stage consisted of a calibration of the surgical instruments and the "wrist hand fingers" unit, with a three-dimensional optical localization system. The guide wire was simulated by a gauged stylet. When the axis and the length of the screw had been determined virtually, insertion of the guide wire was carried out under guidance of the virtual images of the computer's screen, without the assistance of the fluoroscopy. Finally the canulated screw was inserted over the guide wire. Insertion was stopped when the screw reached the intra osseous virtually predetermined length. A check using conventional fluoroscopy made it possible to ensure the correct positioning of the screw. Our results show that it is possible to insert a screw into a scaphoid without conventional fluoroscopy, by using the fluoroscopic navigation system. The procedure was performed without difficulty, apart from the need for calibration of the navigation tools one by one. The solid immobilization device, although having the potential for micromovement, did not lead to any misdirection of the guide wire or screw. Our technique cannot be employed at the moment in live human surgery. Its limits are of a geometrical nature "two images available in two planes", data processing "non-specific software dedicated", instrumental "instrument calibration, micromobility of the immobilisation device" and live surgery "no current validation on a fractured scaphoid". Meantime, the development of a percutaneous scaphoid osteosynthesis procedure by CAS can only bring advantages: reduction in the learning curve, widening of the indications, comfort in the technique, reduction in the errors of ostesynthesis and, reduction in the exposure to x-rays. In the current state of knowledge, the method would only be applicable to undisplaced fractures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Liverneaux. [Scaphoid percutaneous osteosynthesis by screw using computer assisted surgery: an experimental study].. https://doi.org/10.1016/j.main.2005.06.004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Experimental validation of noninvasive referencing in navigated procedures on long bones.

Navigation procedures in orthopedic surgery require fixation of reference markers to the anatomic region of interest. Inadequate fixation might lead to micromotion or loosening of the reference marker, consequently causing registration failures or errors in navigation. Osseous rigid fixation is usually achieved by minimally invasive Schanz screws or pins. The goal of this study was to evaluate a non invasive external fixation device, a headband so far used in cranial navigation, as an alternative invasive fixation technique to reference markers in the femur. A common navigation system with an adapted trauma software application was used to track the positions of the soft tissue-attached headband relative to an invasive reference marker on the femur during manipulations of the thigh. Relative translative and rotational movements of the headband were measured during defined movements of the hip and knee and manipulations of the headband itself. The results revealed high translative and rotational movements, up to 6 mm and 3 degrees , respectively, due to minor manipulations of the affected lower extremity. Noninvasive soft tissue fixation with a headband does not allow rigid fixation for accurate navigated registration or operative procedures at the femur. Necessary intraoperative movements or manipulations would cause substantial registration failures. Invasive fixation techniques with screws or pins are still the method of choice.

Bone Screws↗

Safety of computer-assisted surgery for cannulated hip screws.

Computer-assisted orthopaedic surgery has developed considerably during the past few years. Several manufacturers produce hardware and software for use in trauma surgery. Validation of these systems before clinical application is mandatory to be sure they work accurately and safely. The accuracy of surgical performance is highly correlated with the cut-out percentages of hip screws. In a standardized operative setting, three cannulated hip screws were inserted in each of 20 sawbones. The screws were positioned either by fluoroscopic navigation technique or by conventional operative technique depending on randomization. Our primary aim was to assess whether computer-navigated screw fixation is equally safe compared with conventional screw fixation using fluoroscopy. To determine safety, we investigated number of drilling attempts, screw position, and radiation time. Secondary to these safety parameters, we also compared the operating time between the two procedures to assess the efficiency of computer navigation. Statistical analysis showed no differences regarding accuracy of screw position. Computer-assisted surgery resulted in fewer drilling attempts and less radiation time, with a similar operation time. We believe the currently used navigation system is safe and accurate.

Bone Screws↗

Techniques of posterior C1-C2 stabilization.

Instability of the atlantoaxial complex may result from inflammatory, traumatic, congenital, neoplastic, or degenerative disorders and often requires surgical stabilization. Initial dorsal wiring techniques allow safe fixation but require rigid external immobilization and have been associated with high fusion failure rates. Rigid screw fixation techniques including transarticular screw fixation and C1-C2 rod-cantilever fixation offer higher fusion rates and less need for rigid immobilization but are more technically demanding. C1-C2 fixation using crossing C2 laminar screws offers rigid fixation but without the technical demands of C2 pars placement. The history and techniques of dorsal fixation of the atlantoaxial complex are reviewed, and the success rates and complications of each are discussed.

Bone Screws↗