Novel gas chromatography-mass spectrometry database for automatic identification and quantification of micropollutants.

Abstract

A novel gas chromatography-mass spectroscopy (GC-MS) database for identification and quantification of micropollutants in environmental and food samples is reported. GC retention times, calibration curves, and mass spectra of nearly 700 chemicals were registered in the database, and the GC retention times of registered chemicals in actual samples were predicted from the retention times of n-alkanes measured before sample analysis. Differences between predicted and actual retention times were less than 3 s, an accuracy that is nearly identical to that obtained by analysis of standard substances. After the retention times were predicted, a calibration file for the GC-MS instrument was created from the predicted retention times, calibration curves, and mass spectra of the registered chemicals. With the resulting calibration file, automated identification of all the chemicals in actual samples was possible without the use of standards, and the identification method was as reliable as conventional methods. When the GC inlet, column, and tuning conditions were adjusted using GC-MS performance check standards, relative standard deviations of 20% or less for determination values could be obtained. More than 90% of the chemicals in the database could be detected at a sensitivity sufficient for all practical purposes (100 pg or less). Because each chemical in the database, to which new substances can easily be added, can be determined in 1 h, micropollutants in samples can be analyzed efficiently and inexpensively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kiwao Kadokami, Kyoko Tanada, Katsuyuki Taneda, Katsuhiro Nakagawa. 2005-09-30. Novel gas chromatography-mass spectrometry database for automatic identification and quantification of micropollutants.. https://doi.org/10.1016/j.chroma.2005.06.052. https://pubmed.health/record/pubmed%3A16130790/novel-gas-chromatography-mass-spectrometry-database-for-automatic-identification-and-quantification

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗