PubMed Health⌕ Search

PubMed · 16188563

Generic method for systematic phase selection and method development of biochromatographic processes. Part I. Selection of a suitable cation-exchanger for the purification of a pharmaceutical protein.

Abstract

Even if the first protein therapeutics are now for more than 20 years on the market the selection of suitable adsorbents for the preparative downstream processing (DSP) of these biomolecules as well as the method development towards process conditions are still based mainly on 'trial and error'. Therefore, theses processes are not perfectly efficient, but indeed very time consuming and laborious. In this study a novel systematic method is introduced to find a suitable adsorbent (not necessarily the best one) with appropriate separation parameters for a specific separation with reduced effort. Following this strategy, the adsorbents must first be packed into columns under preparative conditions and then characterized completely with regard to, e.g. pressure drop, k'-values, plate heights (HETP curves), selectivity and capacity by using test substances, which are similar in their characteristics (molecular mass, size, charge distribution, hydrophobicity) to the target proteins. With the database once determined, a preselection of most suitable adsorbents including separation parameters is made regarding chromatographic and also economical properties. After this, preparative experiments must be conducted with a reduced number of adsorbents to figure out the individual influence of side components. This approach is demonstrated for the separation of an exemplary industrial protein mixture using cation-exchange chromatography (CEX). Characterization of different weak CEX-adsorbents is illustrated. After comparing these phases with each other, a first preselection and a prediction of suitable adsorbents is made. In the following preparative separation conditions (load, velocity, gradient) are determined for the preparative separations using the database and results of some additional experiments. The final comparison of separation performance in preparative scale confirms this selection and so the applicability of the new method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin Lohrmann, Michael Schulte, Jochen Strube. 2005-06-15. Generic method for systematic phase selection and method development of biochromatographic processes. Part I. Selection of a suitable cation-exchanger for the purification of a pharmaceutical protein.. https://doi.org/10.1016/j.chroma.2005.05.067

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Synthesis and characterization of a new inorganic cation-exchanger-Zr(IV) tungstomolybdate: analytical applications for metal content determination in real sample and synthetic mixture.

An amorphous sample of inorganic cation-exchanger Zr(IV) tungstomolybdate was prepared by mixing varying ratios of 0.1M aqueous solution of sodium tungstate and 0.1M aqueous solution of sodium molybdate into 0.1M aqueous solution of zirconium oxychloride at pH 1. This cation-exchanger was found to have a good ion-exchange capacity (2.40 mequiv.g(-1) for Na(+)), high thermal and chemical stability. A tentative structural formula was proposed on the basis of chemical composition, FTIR and thermogravimetric analysis. Distribution coefficients (K(d)) values of metal ions in various solvent systems were determined. Some important and analytically difficult quantitative binary separations viz. Ni(II)-Pb(II), Ni(II)-Zn(II), Ni(II)-Cd(II), Mg(II)-Al(III), etc. were achieved. The practical applicability of the cation-exchanger was demonstrated in the separation of Cu(II)-Zn(II) from a synthetic mixture as well as from real samples of pharmaceutical formulation and brass alloy.

Cation Exchange Resins↗

Investigation of a variety of cationic surfactants attached to cation-exchange silica for hydrophobicity optimization in admicellar solid-phase extraction for high-performance liquid and gas chromatography.

A series of cationic surfactants were attached to cation-exchange silica that included silica modified with sulfopropyl groups and unmodified silica to create hydrophobic solid-phase extraction sorbents. Various chain lengths and chain numbers of amine, ammonium and pyridinium-based cationic surfactants were investigated to reach sufficient sorbent hydrophobicity to capture US Environmental Protection Agency (EPA) priority polycyclic aromatic hydrocarbons (PAHs). Of the tested surfactant/silica combinations, dihexadecyldimethylammonium cations attached to unmodified silica resulted in the sorbent having the greatest hydrophobicity. This sorbent provided strong hydrophobic attraction of PAHs and also efficient elution because the PAHs were removed together with the surfactant using a very mild 5% acetic acid in methanol rinse solution. This admicellar solid-phase extraction procedure was applied for the determination of these PAHs for both high-performance liquid and gas chromatography. The detection limits of these PAHs were below the EPA's maximum contaminant level of 0.2 microg/L.

Cation Exchange Resins↗

An improved 62Zn/62Cu generator based on a cation exchanger and its fully remote-controlled preparation for clinical use.

OBJECTIVE: The goal of this study was to develop an improved (62)Zn/(62)Cu generator based on cation exchange resin and remote preparation at high radioactivity scale for clinical use. METHODS: A natural Cu target was irradiated with proton beam in the energy range of 30-->19 MeV at a beam current of 10 muA for 1 h to obtain around 1.7 GBq of (62)Zn. The (62)Zn was isolated from the Cu target on an anion exchange column with more than 97% yield within 2.5 h from the EOB. The (62)Zn/(62)Cu generator was prepared by loading the (62)Zn(2+) on a Sep-Pak plus CM cartridge. RESULTS: The generator showed high elution efficiency ( approximately 96%) using a small volume (ca. 3 ml) of a 200-mM glycine solution with a very low breakthrough of (62)Zn (<0.1%). CONCLUSIONS: This (62)Zn/(62)Cu generator has been proven to be highly useful as a source of (62)Cu for the synthesis of (62)Cu-labeled compounds. The clinical application of [(62)Cu]Cu-ATSM produced with this generator has been already approved by the Institutional Review Board at the National Institute of Radiological Sciences.

Cation Exchange Resins↗