PubMed Health⌕ Search

PubMed · 16196145

Quantitative measurements on wetted thin layer chromatography plates using a charge coupled device camera.

Abstract

This paper presents the first study of imaging of spots on thin-layer chromatographic plates whilst still wet with solvent. Imaging and quantification of Sudan II after development with dichloromethane was carried out in both reflectance and transmission modes, using a charge coupled device (CCD) camera. The relationship between peak area and sample loading was established at low sample loading, and found to be linear over an order of magnitude for both wet and dry modes with r2-values > 0.99. All data processing was carried out using the Beer-Lambert equation. Curvature at high loadings in the plots of integrated absorbance as a function of sample loading was accounted for using an empirical expression designed for use with the Kubelka-Munk treatment and apparent absorbance of the stationary phase due to scattering. Results are consistent with an effective pathlength significantly longer than the thickness of the sorbent layer. The limit of detection on a dry plate (0.5 ng) was found to be lower than on a wetted plate (2 ng). Precision was found to be 1-4% RSD intra-plate and 8-14% RSD inter-plate. Results are compared with quantification of the same analyte on dried plates.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael Lancaster, David M Goodall, Edmund T Bergström, Sean McCrossen, Peter Myers. 2005-10-07. Quantitative measurements on wetted thin layer chromatography plates using a charge coupled device camera.. https://doi.org/10.1016/j.chroma.2005.06.068

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dynamic modeling of an enzymatic membrane reactor for the treatment of xenobiotic compounds.

A membrane enzymatic reactor, consisting of a stirred tank coupled to an ultrafiltration membrane was set up for the enzymatic oxidation of xenobiotic compounds. The azo dye Orange II was selected for the model compound and manganese peroxidase for the oxidative enzyme. The ligninolytic cycle was initiated and maintained by the controlled addition of all factors (reactants, mediators, and stabilizers) at suitable rates. Considering the distinctiveness of this process, in which the substrate to be oxidized is not the primary substrate for the enzyme, a kinetic model was developed. The azo dye concentration and hydrogen peroxide addition rate were found to be the main factors affecting the process. The reaction kinetics was defined using a Michaelis-Menten model with respect to the Orange II concentration and a first-order linear dependence relative to the H(2)O(2) addition rate. The dynamic model, which takes into account both the kinetics and the hydraulics of the system, was validated by comparing the experimental results in continuous operation under steady and non-steady state to model predictions. In particular, the model predicted the behavior of the system when unexpected alterations in steady-state operation occurred. Furthermore, the model allowed us to obtain the most appropriate H(2)O(2)/Orange II ratio in the feed to maximize the process efficiency.

Azo Compounds↗

Highly enantioselective and diastereoselective 1,3-dipolar cycloaddition reactions between azomethine imines and 3-acryloyl-2-oxazolidinone catalyzed by binaphthyldiimine-Ni(II) complexes.

[reaction: see text] We have found the first example of high levels of asymmetric induction (97-74% ee) along with high diastereoselectivity (>99:1-64:36) in dipole-HOMO-/dipolarophile-LUMO-controlled asymmetric 1,3-dipolar cycloaddition reactions between fused azomethine imines and 3-acryloyl-2-oxazolidinone using a chiral BINIM-Ni(II) complex as a chiral Lewis acid catalyst.

Azo Compounds↗