PubMed Health⌕ Search

PubMed · 16257572

Protein components for nanodevices.

Abstract

A long-term goal of nanobiotechnology is to build tiny devices that respond to the environment, perform computations and carry out tasks. Considerable progress has been made in building protein components for such devices, and here we describe examples, including self-assembling protein arrays, pores with triggers and switches, and motor proteins harnessed for specific tasks. A major issue that has been successfully addressed in this recent work is the interface between the proteins and other components of the system, such as a metal surface. While further progress is expected in the coming years, the assembly of devices from the components has seen more limited accomplishments. For example, although a wide variety of sensors based on nanobiotechnology has been developed, unresolved problems still confront the construction of complex nanobioelectronic circuits, and the development of nanorobotics with biological components remains a distant dream.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yann Astier, Hagan Bayley, Stefan Howorka. 2005-10-28. Protein components for nanodevices.. https://doi.org/10.1016/j.cbpa.2005.10.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection and quantification of on-chip phosphorylated peptides by surface plasmon resonance imaging techniques using a phosphate capture molecule.

We describe herein a detection and quantification system for on-chip phosphorylation of peptides by surface plasmon resonance (SPR) imaging techniques using a newly synthesized phosphate capture molecule (i.e., biotinylated zinc(II) complex). The biotinylated compound is a dinuclear zinc(II) complex that is suitable for accessing phosphate anions as a bridging ligand on the two zinc(II) ions. The compound was exposed on the peptide array and detected with streptavidin (SA) via a biotin-SA interaction by SPR imaging. In the conventional method using antibody, both anti-phosphoserine and anti-phosphotyrosine antibodies were required for phosphoserine and phosphotyrosine detection, respectively. Detection of the phosphate group by the zinc(II) complex, however, was independent of the phosphorylated amino acid residues. The calibration curve for the phosphorylation ratios was established with a calibration chip, on which phosphoserine-containing peptide probes were immobilized. The peptide probes, which were phosphorylated on the surface by protein kinase A, were detected and quantified by SPR imaging using the zinc(II) complex, SA, and anti-SA antibody. The reaction rate and the kinetics of on-chip phosphorylation were also evaluated with the peptide array. The phosphorylation ratio was saturated at approximately 20% in 2 h in this study.

Microchip Analytical Procedures↗