PubMed Health⌕ Search

PubMed · 16263479

Lung function tests for pre-school children.

Abstract

There are a few devices for measuring lung function in pre-school children. Neither the interrupter technique nor the forced oscillation techniques have been standardised. We highlight some of the issues around the measurement of airway resistance using the interrupter technique and emphasise that, as with other lung function measurements, operators should have a proper understanding of the methods before they can be applied. Both methods for measuring airway resistance have potential for clinical and research application.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S A McKenzie, P D Bridge, C S Pao. 2001. Lung function tests for pre-school children.. https://doi.org/10.1053/prrv.2000.0100

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.

OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.

Airway Resistance↗

Nitric oxide production in the ventilatory muscles in response to acute resistive loading.

The effect of muscle activation on muscle nitric oxide (NO) production remains controversial. Whereas NO release increases in in vitro activated muscles and in vivo limb muscles, diaphragmatic NO synthase (NOS) activity declines after 3 h of inspiratory resistive loading (IRL). We tested in this study the hypotheses that acute IRL decreases diaphragmatic NO derivatives levels and reduces protein expression of neuronal (nNOS), endothelial (eNOS), and inducible (iNOS) NO synthases, as well as 3-nitrotyrosine formation. Anesthetized, tracheostomized, spontaneously breathing adult rats were subjected to IRL (50% of the maximum inspiratory pressure) for 1, 3, or 6 h. Quietly breathing rats served as controls. After 3 h of IRL, muscle eNOS and nNOS protein levels rose by 80 and 60% of control values, respectively. Whereas eNOS expression did not change any further, nNOS expression reached 550% of control values after 6 h of IRL. Strong iNOS protein expression was detected in the diaphragms after 6 h of IRL. Total NO derivatives levels in the diaphragm declined during IRL as a result of reduction in nitrate, nitrite, and nitrosothiols. Diaphragmatic protein tyrosine nitration decreased in response to IRL, and this reduction was mainly due to reduced tyrosine nitration of enolase and aldolase. We conclude that diaphragmatic NO derivatives levels decline in response to IRL and that the rise in diaphragmatic NOS protein expression may be a compensatory response designed to counterbalance the decline in NOS activity.

Airway Resistance↗