PubMed Health⌕ Search

PubMed · 16283150

[Multislice computed tomographic myelography].

Abstract

While magnetic resonance imaging (MRI) is the first line modality in depicting intramedullary spinal lesions, computed tomographic (CT) myelography has gained renewed attention due to the introduction of multislice scanning (MS-CT). Compared with conventional CT, MS-CT permits rapid, high-resolution imaging of various spinal pathologies with extended scan length. Although soft tissue contrast is inferior to that with MRI, MS-CT myelography performs best in detailed assessment of osseous pathologies, 3D imaging of orthopedic and anesthesiologic implants, and showing dural leakage and causes of CSF circulation impairment. Whenever MRI is not available or contraindicated, MS-CT myelography is the method of choice for evaluating spinal lesions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Klingebiel, F Masuhr, P Rogalla, E Hein, R Juran, H C Bauknecht, G Bohner. 2006. [Multislice computed tomographic myelography].. https://doi.org/10.1007/s00115-005-2011-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Variability in isometric force and moment generating capacity of glenohumeral external rotator muscles.

BACKGROUND: Muscles which cause glenohumeral external rotation possess varying ability for generating force and moment due to differences in muscle architecture, moment arm, and the interaction of these two factors. This study's purpose was to determine a complete dataset of muscle-tendon parameters for predicting the moment generating capacity and force-length dependence for external rotation of infraspinatus, supraspinatus and teres minor muscles. METHODS: Muscle fascicle length, sarcomere length, pennation angle, and muscle volume were measured for sub-regions of infraspinatus and supraspinatus, and teres minor from 10 glenohumeral specimens. Tendon excursion was measured for glenohumeral rotation. From these parameter measurements, optimal fascicle length, physiological cross-sectional area, muscle force-length dependence, and maximum isometric moment generating capacity were calculated. FINDINGS: Substantial differences were found for optimal muscle length, physiologic cross-sectional area, and tendon length for the 10 specimens of this study. Muscle sub-region had a significant effect on the force-length relationship for infraspinatus (P<0.001), but was not significant for supraspinatus (P=0.49). For infraspinatus and supraspinatus, maximum isometric rotation moment capacity was greater at 10 degrees versus 60 degrees abduction (P<0.001). Maximum isometric rotation moment capacity for the teres minor was greater at 10 degrees versus 60 degrees abduction (P<0.01). Sub-regions demonstrated significant differences in isometric moment capacity (P<0.001). INTERPRETATION: Functional capabilities of these muscles depend on muscle architecture and moment arm as well as their combined effects. The results allow for development of stochastic and deterministic models of glenohumeral external rotation strength which can be used for prediction of muscle forces and joint moments.

Anatomy, Cross-Sectional↗

Characterization of pediatric skeletal tumors and tumor-like conditions: specific cross-sectional imaging signs.

The radiograph is indispensable for characterizing pediatric skeletal lesions. However, cross-sectional imaging with CT and MRI can provide additional information and augment or confirm an impression obtained from the initial radiographic findings. This review will highlight the role of CT and MRI in characterizing pediatric skeletal tumors and tumor-like conditions. Focus will be given to the contributions of each modality to the process of characterizing skeletal lesions, recalling that cross-sectional imaging is more commonly obtained for the purpose of determining extent of disease rather than for characterization.

Anatomy, Cross-Sectional↗

State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

Orofacial diagnostic imaging has grown dramatically in recent years. As the use of endosseous implants has revolutionized oral rehabilitation, a specialized technique has become available for the preoperative planning of oral implant placement: cone beam computed tomography (CT). This imaging technology provides 3D and cross-sectional views of the jaws. It is obvious that this hardware is not in the same class as CT machines in cost, size, weight, complexity, and radiation dose. It is thus considered to be the examination of choice when making a risk-benefit assessment. The present review deals with imaging modalities available for preoperative planning purposes with a specific focus on the use of the cone beam CT and software for planning of oral implant surgery. It is apparent that cone beam CT is the medium of the future, thus, many changes will be performed to improve these. Any adaptation of the future systems should go hand in hand with a further dose optimalization.

Anatomy, Cross-Sectional↗