PubMed Health⌕ Search

PubMed · 16284665

All-solid-state reference electrodes based on conducting polymers.

Abstract

A novel construction of solution free (pseudo)reference electrodes, compatible with all-solid-state potentiometric indicator electrodes, has been proposed. These electrodes use conducting polymers (CP): polypyrrole (PPy) or poly(3,4-ethylenedioxythiophene) (PEDOT). Two different arrangements have been tested: solely based on CP and those where the CP phase is covered with a poly(vinyl chloride) based outer membrane of tailored composition. The former arrangement was designed to suppress or compensate cation- and anion-exchange, using mobile perchlorate ions and poly(4-styrenesulfonate) or dodecylbenzenesulfonate anions as immobilized dopants. The following systems were used: (i) polypyrrole layers doped simultaneously by two kinds of anions, both mobile and immobilized in the polymer layer; (ii) bilayers of polypyrrole with anion exchanging inner layer and cation-exchanging outer layer; (iii) polypyrrole doped by surfactant dodecylbenzenesulfonate ions, which inhibit ion exchange on the polymer/solution interface. For the above systems, recorded potentials have been found to be practically independent of electrolyte concentration. The best results, profound stability of potentials, have been obtained for poly(3,4-ethylenedioxythiophene) or polypyrrole doped by poly(4-styrenesulfonate) anions covered by a poly(vinyl chloride) based membrane, containing both anion- and cation-exchangers as well as solid potassium chloride and silver chloride with metallic silver. Differently to the cases (i)-(iii) these electrodes are much less sensitive to the influence of redox and pH interferences. This arrangement has been also characterized using electrochemical impedance spectroscopy and chronopotentiometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anna Kisiel, Honorata Marcisz, Agata Michalska, Krzysztof Maksymiuk. 2005-10-27. All-solid-state reference electrodes based on conducting polymers.. https://doi.org/10.1039/b510868c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a perfusion ion-exchange chromatography method for the separation of soybean proteins and its application to cultivar characterization.

A perfusion ion-exchange chromatography method has been designed, for the first time, for the separation of soybean proteins and its application to the characterization of soybean cultivars. For that purpose, the gradient, the mobile phase composition (buffer concentration, buffer pH, and elution salt), and the temperature were optimized. The method consisted of a two-step gradient (0% B for 2 min and from 0 to 50% B in 10 min) being mobile phase A a 2 0mM borate buffer (pH 9) and mobile phase B a 20 mM borate buffer (pH 9) containing 1M sodium chloride. The procedure used for the preparation of sample solutions was significantly simpler than that proposed by other authors and basically consisted of dissolving in water. This method enabled the separation of soybean proteins from a soybean protein isolate in 11 peaks in about 9 min. The method was used to separate soybean proteins in different commercial soybeans. In general, the 11 peaks yielded by the soybean protein isolate were also observed in the chromatograms of all soybeans. However, the area percentages of every peak in every soybean enabled the differentiation between soybeans. Moreover, the method was also used to separate soybean proteins in the proteic fractions obtained from every soybean. Multivariate methods were used for patterns recognition and the classification of samples.

Chromatography, Ion Exchange↗

An improved method for purification of recombinant truncated heme oxygenase-1 by expanded bed adsorption and gel filtration.

Recombinant truncated human heme oxygenase-1 (hHO-1) expressed in Escherichia coli was efficiently separated and purified from feedstock by DEAE-ion exchange expanded bed adsorption. Protocol optimization of hHO-1 on DEAE adsorbent resulted in adsorption in 0 M NaCl and elution in 150 mM NaCl at a pH of 8.5. The active enzyme fractions separated from the expanded bed column were further purified by a Superdex 75 gel filtration step. The specific hHO-1 activity increased from 0.82 +/- 0.05 to 24.8 +/- 1.8 U/mg during the whole purification steps. The recovery and purification factor of truncated hHO-1 of the whole purification were 72.7 +/- 4.7 and 30.2 +/- 2.3%, respectively. This purification process can decrease the demand on the preparation of feedstock and simplify the purification process.

Chromatography, Ion Exchange↗

Purification and characterization of proline/hydroxyproline-rich glycoprotein from pearl millet coleoptiles infected with downy mildew pathogen Sclerospora graminicola.

Hydroxyproline-rich glycoproteins (HRGPs) are important plant cell wall structural components, which are also involved in response to pathogen attack. In pearl millet, deposition and cross-linking of HRGPs in plant cell walls was shown to contribute to the formation of resistance barriers against the phytopathogenic oomycete Sclerospora graminicola. In the present study, the purification and characterization of HRGPs that accumulated in coleoptiles of pearl millet seedlings in response to S. graminicola inoculation has been carried out. Periodic acid Schiff's staining revealed that the purified protein was a glycoprotein. The protein to carbohydrate ratio was determined to be 95.5%:4.5% (w/w). Proline amounted for 20 mol% of the total amino acids as indicated by amino acid composition analysis. The isolated protein had a pI of 9.8 and was shown to be composed of subunits of 27, 17, and 14 kDa. Cross reactivity with the monoclonal antibody MAC 265 and the presence of the signature amino acid sequence, PVYK, strongly suggested to classify the purified glycoprotein as a member of the P/HRGPs class. In the presence of horseradish peroxidase and H2O2 the purified glycoprotein served as a substrate for oxidative cross-linking processes.

Chromatography, Ion Exchange↗