PubMed Health⌕ Search

PubMed · 16313877

Evolving diagnostic modalities in inflammatory bowel disease.

Abstract

Over the past several years, significant advances have been made in the diagnostic techniques used in the management of ulcerative colitis and Crohn's disease. These advances have occurred mainly in the area of gastrointestinal endoscopy and radiology. Capsule endoscopy and double-balloon endoscopy have permitted better visualization of the small bowel mucosa. Advanced imaging techniques, including chromoendoscopy, magnification endoscopy, confocal endomicroscopy, and spectroscopy, may aid in the diagnosis of colorectal neoplasia in patients with long-standing disease. Improved radiographic imaging techniques based on computed tomography and magnetic resonance imaging allow noninvasive means of evaluating the small bowel in patients with known or suspected Crohn's disease. Finally, positron emission tomography is an investigative tool for inflammatory bowel disease that may also aid in the detection of inflammation in these diseases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jonathan A Leighton, Edward V Loftus. 2005. Evolving diagnostic modalities in inflammatory bowel disease.. https://doi.org/10.1007/s11894-005-0078-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Magnetic resonance colonography vs computed tomography colonography for the diagnosis of colorectal cancer: an indirect comparison.

OBJECTIVE: The primary aim of this study was to use meta-regression techniques to compare the diagnostic accuracy of computed tomography colonography (CTC) and magnetic resonance colonography (MRC), compared with conventional colonoscopy for patients presenting with colorectal cancer (CRC). METHOD: Quantitative meta-analysis was performed using prospective studies reporting comparative data between CTC and MRC individually to conventional colonoscopy. Study quality was assessed and sensitivities, specificities, diagnostic odds ratios (DOR) were calculated. Summary receiver operating characteristic (SROC) curves and sensitivity analysis were utilized. Meta-regression was used to indirectly compare the two modalities following adjustment for patient and study characteristics. RESULTS: Overall sensitivity and specificity for CTC (0.96, 95% CI 0.92-0.99; 1.00, 95% CI 0.99-1.00 respectively) and MRC (0.91, 95% CI 0.79-0.97; 0.98, 95% CI 0.96-0.99 respectively) for the detection of CRC was similar. Meta-regression analysis showed no significant difference in the diagnostic accuracy of both modalities (beta=-0.64, P=0.37 and 95% CI of 0.12-2.39). Both tests showed high area under the SROC curve (CTC=0.99; MRC=0.98), with high DORs (CTC=1461.90, 95% CI 544.89-3922.30; MRC=576.41, 95% CI 135.00-2448.56). Factors that enhanced the overall accuracy of MRC were the use intravenous contrast, faecal tagging and exclusion of low-quality studies. No factors improved diagnostic accuracy from CTC except studies with more than 100 patients (AUC=1.00, DOR=2938.35, 95%CI 701.84-12 302.91). CONCLUSION: This meta-analysis suggested that CTC and MRC have similar diagnostic accuracy for detecting CRC. Study quality, size and intravenous/intra-luminal contrast agents affect diagnostic accuracies. For an exact comparison to be made, studies evaluating CTC, MRC and colonoscopy in the same patient cohort would be necessary.

Colonography, Computed Tomographic↗

Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography.

The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)-CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD-CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm x 16 mm, slice thickness of 3.0mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD-CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm).

Colonography, Computed Tomographic↗