PubMed Health⌕ Search

PubMed · 16333171

Synthetic hydroxyapatite-based integrated orbital implants: a human pilot trial.

Abstract

PURPOSE: Orbital implants are used as fillers following enucleation or evisceration surgeries to replace the lost volume for better cosmesis and motility of the artificial eye. Over the last decade porous hydroxyapatite (HAp) implants derived from the naturally occurring corals, are increasingly used. Recently synthetic HAp-based implants have been introduced. After fibrovasculrisation they have the added advantage of being directly integrated with the artificial shell, thereby increasing the motility to a great extent. The current study, evaluated the efficacy of two different models of synthetic HAp with 75% porosity and pore sizes ranging from 100 to 300 mm. METHODS: Synthetic HAp powders were prepared with a novel wet chemical route. Two models of porous orbital implants with the characteristic designs for both evisceration and enucleation surgery were developed, characterised and implanted to consecutive 25 human subjects, 17 following evisceration, and 8 following enucleation. The postoperative performances of these implants were evaluated in respect to the degree of volume replacement (implant + prosthesis), presence/absence of lagophthalmos and lower eye-lid laxity, status of socket and fornices. Magnetic resonance imaging assessed the stability of the implants within the socket and progressive fibro-vascularisation within the porous scaffold as a function of time. Finally, motility of the implants as well as the prostheses (horizontal movements by Lister Perimeter) and subjective cosmetic results (qualitative) were also evaluated. RESULTS: During the 2.5 years of follow-up study, no significant postoperative complications were noticed. One case, showed an anterior implant exposure of 3-4 mm, and was managed with donor scleral patch graft and one case of conjunctival thinning was corrected by re-suturing the conjunctival dehiscence. Fourteen of the 25 patients had a very good movement of the prostheses (> 20 degrees horizontal movement) and the other 11 patients had a fair motility (10 - 20 degrees). The degree of volume replacement (with prosthesis) was found to be very good in 21 patients and fair in other 4 patients. All patients reported cosmetic satisfaction. CONCLUSION: Synthetic HAp-based integrated orbital implants with this modified design were found clinically safe and cosmetically acceptable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Biswanath Kundu, Mithlesh K Sinha, Santanu Mitra, Debabrata Basu. 2005. Synthetic hydroxyapatite-based integrated orbital implants: a human pilot trial.. https://doi.org/10.4103/0301-4738.18904

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

One step synthesis of silver nanorods by autoreduction of aqueous silver ions with hydroxyapatite: An inorganic-inorganic hybrid nanocomposite.

In this report, a novel method for the synthesis of silver nanoparticles on the surface of hydroxyapatite is described. Hydroxyapatite crystals are synthesized from acid mineralized solution, a byproduct of bone glue industries, by a simple chemical precipitation method, which results in the formation of hydroxyapatite nanocrystals. The reduction of silver ions occurs by the electron transfer from the hydroxyl groups on the surface of hydroxyapatite. This results in the formation of silver nanorods and needle shaped nanoparticles that are bound on the surface of hydroxyapatite, and the observed silver nanocrystals show anisotropic structure. Thus, hydroxyapatite crystals can be used as a new class of inorganic scaffolds for the synthesis of nanomaterials with implications in designing inorganic-inorganic hybrid nanocomposites for different applications.

Durapatite↗

Bioactivity in in situ hydroxyapatite-polycaprolactone composites.

In our previous work, hydroxyapatite (HAP) was synthesized under two conditions: one in the presence of polyacrylic acid (in situ HAP) and the other in the absence of polyacrylic acid (ex situ HAP). Composites of both HAPs with polycaprolactone (PCL) were investigated for their applicability as scaffolds for bone tissue engineering. In the current work, bioactivity of these composites has been investigated by soaking them in simulated body fluid for different intervals of time. Nucleation and growth mechanism of apatite on these composites has also been investigated. Fourier transform infrared spectroscopy study suggests that although apatite growth starts with an intermediate phase, it completely transforms to HAP after 4 days of soaking. Nanoindentation results suggest that the apatite growing on in situ HAP/PCL composites has much higher hardness and elastic modulus as compared to the apatite growing on ex situ HAP/PCL composites. The apatite grown on the ex situ composites has a net-like interconnected structure. The observed differences in mechanical properties and morphology of apatite have been described on the basis of nucleation mechanisms. The nucleation of apatite on the in situ HAP/PCL composites proceeds through the formation of a complex between Ca2+ and COO- groups; on the other hand, nucleation occurs because of dissolution reaction of apatite in ex situ HAP/PCL composites.

Durapatite↗

Instant nano-hydroxyapatite: a continuous and rapid hydrothermal synthesis.

Nano-particle hydroxyapatite (HA) rods, were rapidly synthesised using a three pump continuous hydrothermal process (using a water feed at up to 400 degrees C and at 24 MPa): the product was obtained as a highly crystalline and phase pure material, without the need for an ageing step or subsequent heat treatment.

Durapatite↗