PubMed HealthSearch

PubMed · 1634379

[The temporal bone].

Abstract

Imaging of the temporal bone by high resolution CT scan has become more and more accurate in recent years. Coronal slices are particularly important. We present the anatomy of four temporal bones embedded in plastic material. Coronal sections with a thickness of 2 mm were taken, radiographed and their density measured. Particular interest was given to the three-dimensional relations as well as to the density of bone of important morphological structures such as the labyrinth, middle ear, facial canal, sigmoid sinus, carotid canal and the mastoid. A low density of bone corresponds to the colour blue, a high density to black. Because of the high resolution of the method it was possible to image small and fine structures such as the auditory ossicles, and the perilymphatic and endolymphatic ducts. A three-dimensional reconstruction may well be possible in the future, and the possibilities of this method are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G M Sprinzl, J Mockenhaupt, J Koebke, W F Thumfart. 1992. [The temporal bone].. https://pubmed.ncbi.nlm.nih.gov/1634379/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cardiac cycle extraction from projection data using static signal suppression.

As an extension of the projection-data-based cardiac cycle extraction that we developed previously (W. S. Kim, K. J. Jung, K. D. Lee, J. B. Ra, and Z. H. Cho, "Proceedings, Seventh Annual Meeting of the Society of Magnetic Resonance in Medicine, 1988," p. 958; W. S. Kim, C. W. Mun, D. J. Kim, and Z. H. Cho, Magn. Reson. Med. 13, 25, 1990), a new technique with which one can extract the cardiac cycle by flow-based projection data measurements is described. Because the method uses flow-dependent projection data, it is possible to obtain the cardiac cycle even from regions such as the head, which has virtually no geometrically varying parts, unlike the cardiac region. The signal-to-noise of this flow (such as blood and CSF) based projection data acquisition is further enhanced by the use of the static sample signal suppression technique developed for angiography (J. H. Kim and Z. H. Cho, Magn. Reson. Med. 14, 554, 1990).

Carotid Artery, Internal

Enhanced surgical exposure for the high extracranial internal carotid artery.

The need for enhanced surgical exposure for the high extracranial (Zone III) internal carotid artery is not uncommon. In certain circumstances, the posterior border and angle of the mandible may interfere with access to the distal internal carotid artery (ICA). The use of modified mandibular osteotomies has provided vascular surgeons in our institution with improved exposure of the ICA in selected cases. The intraoral sagittal split and extraoral vertical ramus osteotomies of the mandible allow manipulation of the posterior border and angle of the mandible with low morbidity and minimal postoperative complications. These procedures can be performed for both dentate and edentulous patients without the need for intermaxillary fixation. This paper introduces these modifications and discusses the benefits over previously described methods of mandibular manipulation.

Carotid Artery, Internal