PubMed HealthSearch

PubMed · 1636039

Electronic imaging workstations: ergonomic issues and the user interface.

Abstract

The electronic imaging workstation serves as the interface between an electronic system and a user. Although the performance aspects of electronic displays are crucial considerations in workstation design, experience suggests that human factors in mechanical operation, software accessibility, and workstation environment are also important. Generally, workstations should have monitors arranged horizontally, and the work environment should be designed to minimize glare from lighting fixtures and to accommodate requirements for low luminance. Devices that control the workstation (eg, key pads, track balls) should be designed so that the user can operate primary and auxiliary controls with efficiency of hand and eye movements. Although many innovations in software (eg, graphical user interfaces) have allowed current workstations to be operated by users who have no knowledge of computer operations, further improvements in interactive software are necessary if such systems are to be accepted by radiologists.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Horii. 1992. Electronic imaging workstations: ergonomic issues and the user interface.. https://doi.org/10.1148/radiographics.12.4.1636039

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quality monitoring of soft-copy displays for medical radiography.

As presentation of medical radiographic images on soft-copy displays (cathode ray tubes) becomes increasingly prevalent in electronic radiography, methods of quality assurance must be developed to ensure that radiologists can effectively transfer film-based reading skills. Luminance measurements provide the basis for evaluating the state of soft-copy displays. An integrated approach has been implemented at Mallinckrodt Institute of Radiology (MIR, Washington University, St Louis, MO) that facilitates measurement of geographically distributed soft-copy displays with centralized data logging, performance tracking, and calibration. MIR's central radiology image manager exercises the display station that drives the monitor, harvests the measurement data, stores the results, and submits the resulting data for additional processing. The luminance measurements are collected by a small, portable, photometric instrument designed at MIR that includes a serial port that is accessed via local area terminal service supported by the radiology image manager. The design details of the photometric instrument and example luminance characteristics of several soft-copy displays used at MIR are presented in this report.

Computer Peripherals

Performance characteristics and image fidelity of gray-scale monitors.

Gray-scale monitors are an essential element of electronic radiology, and their ability to provide images that are perceived to be identical to those available on conventional or laser-printed film is crucial to success of electronic radiology. Image fidelity is measured in physical characteristics (luminance, dynamic range, distortion, resolution, and noise) and with psychophysical techniques, including receiver operator characteristics analysis with clinical images and testing with contrast-detail patterns to determine threshold contrast. Currently, laser-printed images facilitate greater information transfer than does a gray-scale monitor because of their higher absolute luminance (500 ft-L vs 60 ft-L), greater perceived dynamic range, and better spatial resolution. In the near future, the developments of gray-scale monitors with 150-200 ft-L luminance, a display standard based on just noticeable differences, and algorithms to improve similarities between gray-scale display images and laser-printed images will help increase the acceptability of monitors as a means to make primary diagnoses.

Computer Peripherals