PubMed Health⌕ Search

PubMed · 16384974

Accommodative changes in lens diameter in rhesus monkeys.

Abstract

PURPOSE: Some debate surrounds the accommodative mechanism in primates, particularly whether the lens equatorial diameter increases or decreases during accommodation. This study has been undertaken to measure the relationship between changes in lens diameter and refraction during accommodation in rhesus monkeys. METHODS: Photorefraction was used to measure accommodation, and goniovideography was used to measure accommodative changes in lens diameter in the iridectomized eyes of two rhesus monkeys. Accommodation was stimulated through the full amplitude available to each eye by stimulation of the Edinger-Westphal nucleus of the brain. Dynamic measurement of refractive changes followed by dynamic measurements of changes in lens diameter for the same stimulus current amplitudes allow the relationship between refraction and lens diameter to be determined. RESULTS: Lens diameter decreased relatively linearly during accommodation by 0.055 mm/diopter (D), resulting in an overall decrease in lens diameter of approximately 7% of the unaccommodated lens diameter for approximately 12 D of accommodation. CONCLUSIONS: The rhesus monkey lens diameter decreases systematically with the refractive change during accommodation in accordance with the Helmholtz accommodative mechanism and in contrast to the accommodative mechanism originally proposed by Tscherning.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adrian Glasser, Mark Wendt, Lisa Ostrin. 2006. Accommodative changes in lens diameter in rhesus monkeys.. https://doi.org/10.1167/iovs.05-0890

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.