PubMed Health⌕ Search

PubMed · 16387177

Microencapsulating hepatocytes.

Abstract

BACKGROUND: Because standardization of the cell microencapsulation procedure has not yet been achieved, we performed hepatocyte microencapsulation using alginate (ALG)-poly-l-lysine (PLL)-ALG (APA) polymer. METHODS: Hepatocytes were microencapsulated using a binozzle air-jet droplet generator. Our study aims were to: (1) clarify how ALG concentration affects the quality of ALG beads; (2) determine how the PLL concentration affects the quality of microcapsules (MCs); (3) ascertain the influence of liquefaction time by sodium citrate (SC) on the quality of the MCs; (4) and clarify how temperature and solution pH, respectively, affect the viability of the hepatocytes inside the MCs. RESULTS: The concentration of ALG must be > or = 3% (w/v) to generate droplets with satisfactory homogeneity in size and roundness (P < .01). The total quantity of PLL molecules is the essential component for MCs (P < .01). As our results show, the numeric ratio of PLL (milligrams) to MCs (milliliters) is roughly 25:1. SC incubation for 8 minutes resulted in the proper thickness of the MC wall; however, the time varied according to the size of the MCs (P < .05). Temperature and pH, although both difficult to control, exerted great influences on cell viability: 4 degrees C and pH 7.2 were found to be optimal by this study (P < .05). CONCLUSIONS: Concentrations of ALG and PLL exerted decisive effects on the quality and strength of MCs. Higher concentrations were suggested. Because temperature and pH greatly affected cell viability, they must be properly monitored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Gao, H C Jiang, J Xu, S H Pan, Y D Li. 2005. Microencapsulating hepatocytes.. https://doi.org/10.1016/j.transproceed.2005.11.026

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protein engineering of Acidovorax facilis 72W nitrilase for bioprocess development.

Hydroxycarboxylic acid monomers can be used to prepare industrially important polymers. Enzymatic production of such hydroxycarboxylic acids is often preferred to chemical production since the reactions are run at ambient temperature, do not require strongly acidic or basic reaction conditions, and produce the desired product with high selectivity at high conversion. However, native enzymes often do not perform desired reactions with the efficiency required for commercial applications. Protein engineering was used to significantly increase the specific activity of nitrilase from Acidovorax facilis 72W for the conversion of 3-hydroxyvaleronitrile to 3-hydroxyvaleric acid. Overexpression of engineered nitrilase enzymes in Escherichia coli, combined with immobilization of whole cells in alginate beads that can be recycled many times has facilitated the development of a commercially viable bioprocess for production of 3-hydroxyvaleric acid.

Alginates↗

Zeta-potentials of alginate-PLL capsules: a predictive measure for biocompatibility?

Alginate-poly-L-lysine (PLL) microencapsulation of cells is a promising approach to prevent rejection in the absence of immunosuppression. Clinical application, however, is hampered by insufficient insight in factors influencing biocompatibility of the capsules. By now, it has been accepted that not only the chemical composition of the materials applied but also other factors contribute to bioincompatibility. The zeta-potential serves as a measure for the electrical charge of the surface and has been shown to be a predictive value for the interfacial reactions between the biomaterial and the surrounding tissue in other applications. In the present study, we have assessed the streaming potential of alginate-PLL capsules composed of either low-, intermediate-, or high-guluronic (G) alginate to calculate the zeta-potential. The zeta-potentials of the capsules were compared to the biological response against the capsules at 4 weeks after implantation in the rat. We show that high-G and low-G alginates provoke a more severe response in the rat than capsules prepared of intermediate-G alginate. This correlates with a higher zeta-potential of the high-G and low-G alginates and by a change in zeta-potential at lower pH. These lower pH-levels are common directly after implantation as the consequence of a host-response associated with mandatory surgery. Our results suggest that we should not only consider the capsule properties under physiological circumstances to explain bioincompatibility but also the capsule features during common pathophysiological situations.

Alginates↗

Effect of immersion disinfection with Perform-ID on alginate, an alginate alternative, an addition-cured silicone and resultant type III gypsum casts.

OBJECTIVE: This study investigated the effect of a commonly used immersion disinfectant upon three different impression materials and any subsequent effects on the abrasion resistance, hardness and surface detail reproduction of gypsum casts. DESIGN: A laboratory study. MATERIALS AND METHODS: Under standardised conditions a total of 120 impressions were made of a ruled test block using irreversible hydrocolloid (Alginoplast), an 'alginate alternative' addition-cure silicone (Position Penta) and a conventional addition-cure silicone (President). The impressions were examined for surface detail reproduction prior to and after disinfection with Perform-ID. The type III casts were evaluated for surface detail reproduction, surface hardness and abrasion resistance. RESULTS: (1) None of the disinfected alginate specimens could reproduce the 50 microm line. (2) Casts produced from the disinfected alginate were significantly less hard than from disinfected Position Penta and President (P <0.001). (3) Disinfection significantly affected the abrasion resistance of casts made from Position Penta (P = 0.029). (4) Disinfection did not significantly affect President or its subsequent casts (P >0.05). CONCLUSION: If disinfecting with Perform-ID, the impression should be made with a conventional addition-cured silicone if good surface detail reproduction of the impression material and a hard and abrasion resistant type III gypsum cast are required.

Alginates↗