PubMed Health⌕ Search

PubMed · 16404317

Solution to a slippery problem in theater.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Amir Nakhdjevani, Simon Mackey, John Pereira. 2006. Solution to a slippery problem in theater.. https://doi.org/10.1097/01.prs.0000184337.23481.ef

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Understanding submucosal electrosurgery for the treatment of nasal turbinate enlargement.

The surgical management of inferior turbinate enlargement is controversial. Submucosal electrosurgical techniques for turbinate reduction include conventional diathermy, radiofrequency tissue reduction and coblation. All electrosurgical techniques use radiofrequency electricity to damage turbinate tissue but differ in the control and delivery of energy. This review will examine the history of submucosal electrosurgery and clarify the various techniques. This review will also examine the evidence for the efficacy and safety of electrosurgery for the treatment of nasal turbinate enlargement, and will make a case that no progress will be made in clinical trials on the safety and efficacy unless there is standardisation of equipment and techniques in nasal electrosurgery.

Diathermy↗

Measurement of the specific heat capacity of liver phantom.

Phantoms are often used to simulate tissue during the development, testing and calibration of medical devices. In order to infer the specific absorption rate (SAR) and resistive heating in phantoms from temperature measurements, the specific heat capacity and density of the phantom are needed. Stauffer et al (2003 Int. J. Hyperth. 19 89-101) developed several phantoms that mimic dielectric properties of liver tissue at 915 MHz. However, thermal properties of the phantoms were not presented. We have measured specific heat capacities and densities for these phantoms. We also present dielectric properties for these phantoms measured from 0.7 to 20 GHz, including 2.45 GHz--a commonly used frequency for microwave hyperthermia and ablation.

Diathermy↗

An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units.

Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.74.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists.

Diathermy↗