Characterizing radial undersampling artifacts for cardiac applications.

Abstract

The undersampled radial acquisition has been widely employed for accelerated (by a factor R = N(r)/N(p)) cardiac imaging, but the resulting reduction in image quality has not been well characterized. This investigation presents a method of measuring these artifacts through synthetic undersampling of high SNR images (SNR > or = 30). After validating the method in phantoms, the method was applied to a study of short-axis, long-axis, and coronary MRI imaging in healthy subjects. For 60 projections (60 N(p)), the total artifact is approximately 10% for short and long-axis imaging (R = 2.1) and approximately 15% for coronary MRI (R = 3.7). For 60 N(p), the SD of artifact in the region of the heart is 2% for short- and long-axis imaging (R = 2.1) and 3.5% for coronary MRI (R = 3.7). The artifact content is less in the region of the heart than in the periphery. The artifact is very reproducible among subjects for standard views. A study of coronary MRI at progressively fewer projections (at constant scan time) showed that right coronary MRI images were acceptable if total artifact was <6.5% of image content (N(p) > 120, R = 2.1).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dana C Peters, Pratik Rohatgi, René M Botnar, Susan B Yeon, Kraig V Kissinger, Warren J Manning. 2006. Characterizing radial undersampling artifacts for cardiac applications.. https://doi.org/10.1002/mrm.20782

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2&#x2009;&#xb5;m &#xd7; 2&#x2009;&#xb5;m resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗