A BASIC computer program for analyzing endpoint assays.

Abstract

We present a computer program that is based on Karber's approximation of endpoint titers, written in GW-BASIC and provides an easy means for analyzing the results of dilution endpoint assays. The program provides estimates of standard error that are not possible from other statistical procedures for this type of data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Lynn. 1992. A BASIC computer program for analyzing endpoint assays.. https://pubmed.ncbi.nlm.nih.gov/1642896/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mass isotopomer distribution analysis: a technique for measuring biosynthesis and turnover of polymers.

Mass isotopomer distribution analysis (MIDA) is a technique for measuring biosynthesis and turnover of polymers in vivo. A stable isotopically enriched precursor is administered, and the relative abundances of different mass isotopomers in the polymer of interest are measured by mass spectrometry (MS). By comparison of statistical distributions predicted from the binomial or multinomial expansion to the pattern of excess isotopomer frequencies observed in the polymer, the enrichment of the biosynthetic precursor subunits (p) for newly synthesized polymers is calculated. MIDA thereby provides a solution to the problem of determining the isotope content in the actual precursor molecules that entered a particular polymeric product (the "true" precursor). The fraction of polymer molecules in a mixture that were newly synthesized during an isotopic experiment (fractional synthesis) can then be calculated. We describe some mathematical characteristics of MIDA and point out certain advantageous features. For example, mathematical estimates of p remain valid even if there does not exist a single anatomic or functional precursor pool. The interpretation of decay curves of endogenously labeled polymers may be improved by the use of higher mass isotopomers, which better fulfill the assumption of flash labeling. By combining fractional synthesis values with rate constants of decay, absolute endogenous synthesis rates can be calculated. Thus, by using probability logic combined with MS analysis, MIDA allows dynamic measurements to be made through analyses on a polymer alone during both isotopic incorporation and decay phases. The method has been applied to fatty acids, cholesterol, and glucose and is potentially applicable to nucleic acids, porphyrins, perhaps proteins, and many other classes of polymers.

Indicator Dilution Techniques

Reliability of the microdilution technic for detection of methicillin-resistant strains of staphylococcus aureus.

To determine whether the microdilution technic for antimicrobic susceptibility testing could detect the hetero-resistance of "methicillin"-resistant Staphylococcus aureus, 100 stock cultures (54 methicillin-susceptible and 46 methicillin-resistant) were tested against methicillin, oxacillin, nafcillin and cephalothin. Each drug was diluted in Mueller-Hinton broth and in Mueller-Hinton broth with 5% NaCl. Minimum inhibitory concentration (MIC) determinations were made after 20-24 hours at 35 C and again after 48 hours of incubation. With one exception, methicillin resistance was detected in Mueller-Hinton broth when the trays were reincubated and read after 48 hours. Earlier detection of methicillin resistance was possible when the penicillinase-stable penicillins were diluted in broth containing 5% NaCl. Further studies suggest that the addition of NaCl to the broth medium might improve the stabilities of methicillin, oxacillin, and nafcillin during storage of the frozen microdilution trays. Either nafcillin or oxacillin would appear to be the best representative of the penicillinase-stable penicillins. Standardized disk-diffusion tests with cephalothin disks indicated that most methicillin-resistant strains are susceptible to cephalothin. However, there is reason to believe that such in-vitro test results might be inappropriate. With microdilution tests, most methicillin-resistant isolates were more resistant to cephalothin than were the methicillin-susceptible strains, but the MIC's for both types of staphylococci were generally within the range of concentrations that can be obtained during therapy. The addition of NaCl to the microdilution tests with cephalothin did not alter the test results significantly.

Indicator Dilution Techniques