PubMed Health⌕ Search

PubMed · 16437287

Improved strategy for comparing microbial assemblage fingerprints.

Abstract

Microbial fingerprinting techniques permit the rapid visualization of entire assemblages in single assays, allowing direct comparison of communities in different samples, where the null hypothesis of such analyses is that all samples are the same. The comparison of fingerprints relies upon the precise estimation of all amplified DNA fragment lengths, which correspond to operational taxonomic units (OTU; analogous, but not equal to, a taxon in macroorganism studies). However, computer interpolation of size standards (and consequently OTU size calling) can be imprecise between gel runs, which can lead to imprecise calculation of similarity indices between multiple assemblages. To account for OTU size calling imprecision, all fragments within a range of sizes (a window) can be combined (i.e., "binned") where the window is as wide as the imprecision of OTU size calling. However, artifacts may occur upon binning samples that may cause samples to appear less similar to each other, caused by splitting of OTU between adjacent bin windows. In this work we present an improved binning technique that accounts for OTU size calling imprecision in the comparison of multiple fingerprints. This technique comprises binning all pairwise comparisons in multiple bin window frames, where the starting size of the window (i.e., frame) is shifted by +1 bp for a total of x frames, where x bp is the width of the maximum bin window size in any binning scheme. Pairwise similarity indices between different community fingerprints are calculated for each of the x frames. To best address the null hypothesis of the community comparison, the maximum similarity value of all x frames is then used in downstream analyses to compare the communities. We believe this binning technique provides the most accurate and least biased comparison between different microbial fingerprints.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ian Hewson, Jed A Fuhrman. 2006-02-01. Improved strategy for comparing microbial assemblage fingerprints.. https://doi.org/10.1007/s00248-005-0144-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗