Laser-driven microsecond temperature cycles analyzed by fluorescence polarization microscopy.

Abstract

We demonstrate a novel technique to achieve fast thermal cycles of a small sample (a few femtoliters). Modulating a continuous near-infrared laser focused on a metal film, we can drive the local temperature from 130 to 300 K and back, within a few microseconds. By fluorescence microscopy of dyes in a thin glycerol film, we record images of the hot spot, calibrate its temperature, and follow its variations in real time. The temperature dependence of fluorescence anisotropy, due to photophysics and rotational diffusion, gives a steady-state temperature calibration between 200 and 350 K. From 200 to 220 K, we monitor temperature more accurately by fluorescence autocorrelation, a probe for rotational diffusion. Time-resolved measurements of fluorescence anisotropy give heating and cooling times of a few microseconds, short enough to supercool pure water. We designed our method to repeatedly cycle a single (bio)molecule between ambient and cryostat temperatures with microsecond time resolution. Successive measurements of a structurally relevant variable will decompose a dynamical process into structural snapshots. Such temperature-cycle experiments, which combine a high time resolution with long observation times, can thus be expected to yield new insights into complex processes such as protein folding.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rob Zondervan, Florian Kulzer, Harmen van der Meer, Jos A J M Disselhorst, Michel Orrit. 2006-01-27. Laser-driven microsecond temperature cycles analyzed by fluorescence polarization microscopy.. https://doi.org/10.1529/biophysj.105.075168

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surface treatment on diffusion and domain formation in supported lipid bilayers.

Supported lipid bilayers are widely used as model systems due to their robustness. Due to the solid support, the properties of supported lipid bilayers are different from those of freestanding bilayers. In this article, we examine whether different surface treatments affect the properties of supported lipid bilayers. It will be shown that depending on the treatment method, the diffusion of the lipids can be adjusted approximately threefold without altering the composition. Additionally, as the bilayer-support interaction decreases, it becomes easier to form coexisting liquid-ordered and liquid-disordered domains. The physical/chemical alterations that result from the different treatment methods will be discussed.

Diffusion↗

An early example of evidence-based medicine: hypoxemia due to nitrous oxide.

Diffusion anoxia. By Bernard Raymond Fink. Anesthesiology 1955; 16:511-14. In 1955, Dr. Bernard Raymond Fink published his findings that described the mechanism by which hypoxemia occurred when nitrous oxide-oxygen anesthesia was discontinued and room air breathing commenced. Using an ear oximeter and brachial artery blood gases, he measured oxygen saturation in eight healthy patients who had received 75% nitrous oxide-25% oxygen for gynecologic surgery. He showed that oxygen saturation decreased from 5% to 10% and often reached a value below 90% when the patient began room air breathing after the nitrous oxide-oxygen was discontinued. The effect was seen over a 10-min period. He concluded that "anoxia arises because the outward diffusion of nitrous oxide lowers the alveolar partial pressure of oxygen." This phenomenon can become a causative factor of cardiac arrest in patients with impaired pulmonary or cardiac reserves.

Diffusion↗