PubMed Health⌕ Search

PubMed · 16445959

Stimulus factors affecting illusory rebound motion.

Abstract

Stimulus attributes that influence a recently reported illusion called "illusory rebound motion" (IRM; [Hsieh, P.-J., Caplovitz, G. P., & Tse, P. U. (2005). Illusory rebound motion and the motion continuity heuristic. Vision Research, 45, 2972-2985.]) are described. When a bar alternates between two different colors, IRM can be observed to traverse the bar as if the color were shooting back and forth like the opening and closing of a zipper, even though each color appears in fact all at once. Here, we tested IRM over dynamic squares or disks defined by random dot or checkerboard textures to show that (1) IRM can be perceived in the absence of first-order motion-energy (or when the direction of net first-order motion-energy is ambiguous); (2) the direction of IRM is multistable and can change spontaneously or be changed volitionally; and (3) the perceived frequency of IRM is affected by several factors such as the contours of the stimulus, stimulus texture, and motion-energy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P-J Hsieh, P U Tse. 2006-01-30. Stimulus factors affecting illusory rebound motion.. https://doi.org/10.1016/j.visres.2005.11.028

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗