PubMed Health⌕ Search

PubMed · 16450036

Negative pressure pinched sample injection for microchip-based electrophoresis.

Abstract

A simple method for injecting well-defined non-biased sample plugs into the separation channel of a microfluidic chip-based capillary electrophoresis system was developed by a combination of flows generated by negative pressure, electrokinetic and hydrostatic forces. This was achieved by using only a single syringe pump and a single voltage supply at constant voltage. In the loading step, a partial vacuum in the headspace of a sealed sample waste reservoir was produced using a syringe pump equipped with a 3-way valve. Almost instantaneously, sample was drawn from the sample reservoir across the injection intersection to the sample waste reservoir by negative pressure. Simultaneously, buffer flow from the remaining two buffer reservoirs pinched the sample flow to form a well-defined sample plug at the channel intersection. In the subsequent separation stage, the vacuum in headspace of the sample waste reservoir was released to terminate all flows generated by negative pressure, and the sample plug at the channel intersection was electrokinetically injected into the separation channel under the potential applied along the separation channel. The liquid levels of the four reservoirs were optimized to prevent sample leakage during the separation stage. The approach considerably simplified the operations and equipment for pinched injection in chip-based CE, and improved the throughput. Migration time precisions of 3.3 and 1.5% RSD for rhodamine123 (Rh123) and fluorescein sodium (Flu) in the separation of a mixture of Flu and Rh123 were obtained for 56 consecutive determinations with peak height precisions of 6.2% and 4.4% RSD for Rh123 and Flu, respectively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lei Zhang, Xuefeng Yin, Zhaolun Fang. 2006-01-11. Negative pressure pinched sample injection for microchip-based electrophoresis.. https://doi.org/10.1039/b511924c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.

Electrophoresis, Microchip↗

Rapid on-column analysis of glucosamine and its mutarotation by microchip capillary electrophoresis.

A novel electrophoretic microchip method for analyzing alpha- and beta-d-glucosamine and their interconversion in solution is presented. d-Glucosamine is labeled with fluorescamine and analyzed by capillary electrophoresis in under 2 min revealing its pH-dependent mutarotation between the alpha- and beta-anomers. The forward interconversion rates for the labeled sugars, based on an iterative analysis of the plateau heights between the peaks, are 0.72+/-0.09, 1.3+/-0.1, and 2.2+/-0.3 x 10(-3)s(-1) at pH 8.99, 9.51 and 10.01, respectively. In a separate experiment, the mutarotation of the unlabeled alpha-d-anomer was followed; the relative intensities of the alpha- and beta-peaks as a function of reaction time at pH 9.51 give a forward rate constant of 0.6+/-0.1 x 10(-3)s(-1). These results demonstrate that fast microchip separations, previously exploited for amine, amino acid, and nucleobase analysis, can also be used to analyze amino sugars and their mutarotation.

Electrophoresis, Microchip↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗