PubMed Health⌕ Search

PubMed · 16484113

The interval for interference in conscious visual imagery.

Abstract

Three experiments are described that use dynamic visual noise (DVN) to interfere with words processed under visual and verbal processing instructions. In Experiment 1 DVN is presented to coincide with the encoding of the words or to coincide with the interval between encoding and recall. The results show that while DVN is a robust disruptor when it is applied during encoding to words processed under visual instruction, it has no effect during encoding when the words are processed under rote instruction. Moreover, DVN has no effect when it is applied during the retention interval, no matter what means are employed to encode the words. Experiment 2 extends these findings by again showing no effect of DVN during the retention interval, yet showing robust interference effects for visually processed words during recall. Finally, Experiment 3 demonstrates that the results of Experiments 1 and 2 cannot be explained by a difference in the time duration associated with application of DVN during the retention interval compared to during encoding and recall. Moreover, the differing decay functions for visually and verbally processed words during the intervals used in Experiment 3 suggest that any failure to cause interference is not because the two processing instructions resulted in words being retained in the same medium. The functions are consistent with word storage mechanisms reflecting appropriately verbal and visual properties. The results are discussed in terms of current models of visual working memory. It is argued that a full interpretation of the results requires a buffer mechanism as an important component of any model of visual working memory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J G Quinn, Jean McConnell. 2006. The interval for interference in conscious visual imagery.. https://doi.org/10.1080/09658210500210019

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A low glycaemic index breakfast cereal preferentially prevents children's cognitive performance from declining throughout the morning.

This study investigated whether the glycaemic index (GI) of breakfast cereal differentially affects children's attention and memory. Using a balanced cross-over design, on two consecutive mornings 64 children aged 6-11 years were given a high GI cereal and a low GI cereal in a counterbalanced order. They performed a series of computerised tests of attention and memory, once prior to breakfast and three times following breakfast at hourly intervals. The results indicate that children's performance declines throughout the morning and that this decline can be significantly reduced following the intake of a low GI cereal as compared with a high GI cereal on measures of accuracy of attention (M=-6.742 and -13.510, respectively, p<0.05) and secondary memory (M=-30.675 and -47.183, respectively, p<0.05).

Attention↗

Inhibitory control test is a simple method to diagnose minimal hepatic encephalopathy and predict development of overt hepatic encephalopathy.

OBJECTIVES: To compare inhibitory control test (ICT), a simple/rapid test of attention, to a standard psychometric battery (SPT) to diagnose minimal hepatic encephalopathy (MHE) and predict development of overt hepatic encephalopathy (OHE) in cirrhotic patients. METHODS: Fifty nonalcoholic cirrhotics and 50 age/educational-status-matched controls were given ICT and SPT in the same sitting. Performance impaired beyond two standard deviations of controls was considered MHE in cirrhotics. ICT results (lure/target response and lures/person) were compared between controls and cirrhotics and within cirrhotics with/without MHE. Receiver-operating characteristic analysis was used to study ICT for MHE diagnosis. Twenty subjects were administered SPT and ICT twice to assess test-retest reliability. All cirrhotics were followed routinely for the development of OHE. RESULTS: Cirrhotics performed worse than controls on SPT and ICT. Using SPT, 39 cirrhotics had MHE. ICT was administered faster than SPT (15 vs 37 min). Cirrhotics with MHE had significantly higher lure (28%vs 3%) and lower target response (91%vs 96%) compared with those without MHE. Lure/person >5 had 90% sensitivity/specificity for MHE diagnosis. AUC for receiver-operating characteristic for lures alone was 95.8%. Lure and target responses were highly correlated (r= 0.9) between sessions showing high test-retest reliability. Five (10%) patients developed OHE on f/u of 26 +/- 10 months; all five had been diagnosed with MHE using ICT and SPT. None of the five patients with discordant results on SPT and ICT developed OHE. CONCLUSIONS: ICT has good sensitivity/specificity for MHE diagnosis, is reliable and is equivalent to SPT for predicting OHE development.

Attention↗