A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis.

Abstract

We have developed a prototype three-channel microfluidic chip that is capable of generating a linear concentration gradient within a microfluidic channel and is useful in the study of bacterial chemotaxis. The linear chemical gradient is established by diffusing a chemical through a porous membrane located in the side wall of the channel and can be established without through-flow in the channel where cells reside. As a result, movement of the cells in the center channel is caused solely by the cells chemotactic response and not by variations in fluid flow. The advantages of this microfluidic chemical linear gradient generator are (i) its ability to produce a static chemical gradient, (ii) its rapid implementation, and (iii) its potential for highly parallel sample processing. Using this device, wildtype Escherichia coli strain RP437 was observed to move towards an attractant (e.g., l-asparate) and away from a repellent (e.g., glycerol) while derivatives of RP437 that were incapable of motility or chemotaxis showed no bias of the bacteria's distribution. Additionally, the degree of chemotaxis could be easily quantified using this assay in conjunction with fluorescence imaging techniques, allowing for estimation of the chemotactic partition coefficient (CPC) and the chemotactic migration coefficient (CMC). Finally, using this approach we demonstrate that E. coli deficient in autoinducer-2-mediated quorum sensing respond to the chemoattractant l-aspartate in a manner that is indistinguishable from wildtype cells suggesting that chemotaxis is insulated from this mode of cell-cell communication.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jinpian Diao, Lincoln Young, Sue Kim, Elizabeth A Fogarty, Steven M Heilman, Peng Zhou, Michael L Shuler, Mingming Wu, Matthew P DeLisa. 2005-12-13. A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis.. https://doi.org/10.1039/b511958h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Differential cell signaling testing for cell-cell communication inference from single-cell data by dominoSignal.

MOTIVATION: Algorithms for ligand-receptor network inference have emerged as commonly used tools to estimate cell-cell communication from reference single-cell data. Many studies employ these algorithms to compare signaling between conditions and lack methods to statistically identify signals that are significantly different. We previously developed the cell communication inference algorithm Domino, which considers ligand and receptor gene expression in association with downstream transcription factor activity scoring. We developed the dominoSignal software to innovate upon Domino and extend its functionality to test statistically differential cellular signaling. RESULTS: This new functionality includes the compilation of active signals as linkages from multiple subjects in a single-cell data set and testing condition-dependent signaling linkage. The software is applicable for analysis of single-cell data sets with multiple subjects as biological replicates as well as with bootstrapped replicates from data sets with few or pooled subjects. We use simulation studies to benchmark the number of subjects in compared groups and cells within an annotated cell type sufficient to accurately identify differential linkages. We demonstrate the application of the Differential Cell Signaling Test (DCST) in the dominoSignal software to investigate consequences of cancer cell phenotypes and immunotherapy on cell-cell communication in tumor microenvironments. These applications in cancer studies demonstrate the ability of differential cell signaling analysis to infer changes to cell communication networks from therapeutic or experimental perturbations, which is broadly applicable across biological systems. AVAILABILITY: dominoSignal is available through Bioconductor at https://www.bioconductor.org/packages/release/bioc/html/dominoSignal.html.

Cell Communication↗

ZAP-70 kinase regulates HIV cell-to-cell spread and virological synapse formation.

HIV efficiently spreads in lymphocytes, likely through virological synapses (VSs). These cell-cell junctions share some characteristics with immunological synapses, but cellular proteins required for their constitution remain poorly characterized. We have examined here the role of ZAP-70, a key kinase regulating T-cell activation and immunological synapse formation, in HIV replication. In lymphocytes deficient for ZAP-70, or expressing a kinase-dead mutant of the protein, HIV replication was strikingly delayed. We have characterized further this replication defect. ZAP-70 was dispensable for the early steps of viral cycle, from entry to expression of viral proteins. However, in the absence of ZAP-70, intracellular Gag localization was impaired. ZAP-70 was required in infected donor cells for efficient cell-to-cell HIV transmission to recipients and for formation of VSs. These results bring novel insights into the links that exist between T-cell activation and HIV spread, and suggest that HIV usurps components of the immunological synapse machinery to ensure its own spread through cell-to-cell contacts.

Cell Communication↗

Gap junctional intercellular communication capacity by gap-FRAP technique: a comparative study.

Gap junctions play an important role in vital functions, including the regulation of cell growth and cell differentiation. Connexins 43 (Cx43) are the most widely expressed gap junction proteins. Cellular localization of phosphorylated Cx43 has been implicated in the capacity of gap junctional intercellular communication (GJIC). To follow the functionality of GJIC of different cell types, in monolayer cultures, characterized by different patterns of phosphorylated Cx43, we used a fluorescence recovery after photobleaching (FRAP) technique, and compared two tracers, 5(6)-carboxyfluorescein diacetate (CFDA) and calcein acetoxymethylester (AM). The GJIC capacity was quantified by estimating fluorescence redistribution parameters. The functionality of GJIC was in relation with the staining localization of phosphorylated Cx43 to the cell-cell contact areas, corresponding to gap junctions between contacting cells. GJIC involvement in fluorescence restitution after photobleaching was checked by a gap junction channel inhibition assay. We demonstrated that the choice of the dye did not significantly influence the fluorescence recovery percentages despite a cell line-dependent CFDA release, whereas it had an important impact on fluorescence kinetic profiles. This study reinforces the interest of the gap-FRAP approach to quantify modifications in the functionality of gap junctions and, above all, argues about the limits of CFDA for 3-D future approaches.

Cell Communication↗