PubMed Health⌕ Search

PubMed · 16512258

Water-soluble vitamins.

Abstract

Simultaneous Determination of Vitamins.--Klejdus et al. described a simultaneous determination of 10 water- and 10 fat-soluble vitamins in pharmaceutical preparations by liquid chromatography-diode-array detection (LC-DAD). A combined isocratic and linear gradient allowed separation of vitamins in 3 distinct groups: polar, low-polar, and nonpolar. The method was applied to pharmaceutical preparations, fortified powdered drinks, and food samples, for which results were in good agreement with values claimed. Heudi et al. described a separation of 9 water-soluble vitamins by LC-UV. The method was applied for the quantification of vitamins in polyvitaminated premixes used for the fortification of infant nutrition products. The repeatability of the method was evaluated at different concentration levels and coefficients of variation were <6.5%. The concentrations of vitamins found in premixes with the method were comparable to the values declared. A disadvantage of the methods mentioned above is that sample composition has to be known in advance. According to European legislation, for example, foods might be fortified with riboflavin phosphate or thiamin phosphate, vitamers which are not included in the simultaneous separations described. Vitamin B2.--Viñas et al. elaborated an LC analysis of riboflavin vitamers in foods. Vitamin B2 can be found in nature as the free riboflavin, but in most biological materials it occurs predominantly in the form of 2 coenzymes, flavin mononucleotide (FMN) and flavin-adenine dinucleotide (FAD). Several methods usually involve the conversion of these coenzymes into free riboflavin before quantification of total riboflavin. According to the authors, there is growing interest to know flavin composition of foods. The described method separates the individual vitamers isocratically. Accuracy of the method is tested with 2 certified reference materials (CRMs). Vitamin B5.-Methods for the determination of vitamin B5 in foods are limited because of their low sensitivity and poor selectivity. Pakin et al. proposed a post-column derivatization of pantothenic acid as a fluorescent compound and used this principle in a specific and sensitive method for the determination of free and bound pantothenic acid in a large variety of foods. A French laboratory invited European laboratories to participate in a series of collaborative studies for this method, which will be carried out in 2005/2006. A more sophisticated method was described by Mittermayer et al. They developed an LC-mass spectrometry (LC/MS) method for the determination of vitamin B5 in a wide range of fortified food products. Application of the method to various samples showed consistent results with those obtained by microbiology. Vitamin B6.-Method 2004.07, an LC method for the analysis of vitamin B6 in reconstituted infant formula, was published by Mann et al. In contrast with this method, which quantifies vitamin B6 after converting the phosphorylated and free vitamers into pyridoxine, Viñas et al. published an LC method which determines 6 vitamin B6 related compounds, the 3 B6 vitamers, their corresponding phosphorylated esters, and a metabolite. Accuracy was determined using 2 CRMs. Results were within the certified ranges. Vitamin C.-Franke et al. described an extensive study to vitamin C and flavonoid levels of fruits and vegetables consumed in Hawaii. Vitamin C was determined by measuring ascorbic acid in its reduced state by LC and coulometric detection along with UV absorbance detection at 245 nm. No attempts were made to assess levels of dehydroascorbic acid. Most recent research revealed that cell uptake of dehydroascorbic acid is unlikely to play a major role, which may explain the very low vitamin C activity of orally administered L-dehydroascorbic acid in rats. The food levels found by Franke et al. are variably lower, higher, or equal in comparison to other studies. Iwase described a method for the determination of ascorbic acid in foods using L-methionine for the pre-analysis sample stabilization. Electrochemical detection was used for the quantification. Traditionally, metaphosphoric acid was proven to be a useful dissolving agent for the determination of ascorbic acid. However, it dissolves in water very slowly, it is hygroscopic, and accurate weighing is not easy. Adjustment at pH 2-3 takes a long time. It appeared to be possible to replace metaphosphoric acid by 0.2% phosphoric acid. Methionine played an important role on the stability of ascorbic acid. The method seemed to be applicable to the routine analysis of ascorbic acid in foods. Folic Acid.-Microbiological analysis of total folate in foods is often considered as the golden standard compared to other methods based on, for example, LC. Koontz et al. showed results of total folate concentrations measured by microbiological assay in a variety of foods. Samples were submitted in a routine manner to experienced laboratories that regularly perform folate analysis fee-for-service basis in the United States. Each laboratory reported the use of a microbiological method similar to the AOAC Official Method for the determination of folic acid. Striking was, the use of 3 different pH extraction conditions by 4 laboratories. Only one laboratory reported using a tri-enzyme extraction. Results were evaluated. Results for folic acid fortified foods had considerably lower between-laboratory variation, 9-11%, versus >45% for other foods. Mean total folate ranged from 14 to 279 microg/100 g for a mixed vegetable reference material, from 5 to 70 microg/100 g for strawberries, and from 28 to 81 microg/100 g for wholemeal flour. One should realize a large variation in results, which might be caused by slight modifications in the microbiological analysis of total folate in foods or the analysis in various (unfortified) food matrixes. Furthermore, optimal combination of enzymes and reaction conditions may vary depending on the composition of the food. Padrangi and Laborde showed recently that treatment with alpha-amylase had no significant effect on measured folate in spinach, although addition of protease significantly increased the release of folate. LC/MS applications gain increasing attention because of their specificity. Rychlik used stable isotope dilution assays for the determination of the folate content of broccoli and bread. Compared to data in the literature and food data bases, amounts were significantly lower. Pawlosky et al., however, found comparable values for 5-methyltetrahydrofolic acid and folic acid by HPLC analysis with fluorescent detection and HPLC/MS. Among samples analyzed were CRMs and broccoli. Besides folic acid, other water-soluble vitamins were also determined by LC/MS/MS by Leporati et al. The method was applied to the quantitative analysis of the natural content of vitamins in typical Italian pasta samples, as well as in fortified pasta samples produced for the U.S. market. Biotin.-A paper from Staggs et al. included the assertion that existing biotin data in food composition tables are inaccurate because the majority are based on bioassays with all relevant disadvantages. Data in most cases are overestimated with consequences for recommendations for dietary biotin intake. An HPLC/avidin-binding assay was used to analyze 87 foods to support the hypothesis mentioned.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Erik J M Konings, Committee on Food Nutrition. Water-soluble vitamins.. https://pubmed.ncbi.nlm.nih.gov/16512258/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New strategies to screen for endocrine-disrupting chemicals in the Portuguese marine environment utilizing large volume injection-capillary gas chromatography-mass spectrometry combined with retention time locking libraries (LVI-GC-MS-RTL).

A new analytical strategy to screen for endocrine-disrupting chemicals (EDCs) in environmental matrices is presented. The strategy uses solid-phase extraction followed by large volume injection and capillary gas chromatography coupled to mass spectrometry combined with retention time locking libraries (SPE-LVI-GC-MS-RTL). Characterization of the proposed methodology (SPE-LVI-GC-MS) for selected classes of EDCs enabled high reproducibility and robustness at the ultratrace level. The RTL databases used allowed hundreds of non-target semivolatiles (i.e., pesticides, polycyclic aromatic hydrocarbons, polychlorinated biphenyls and other classes of suspected EDCs from a great number of unknown environmental matrices) to be simultaneously screened for in an easy, fast and remarkable manner. The application of the proposed methodology to real environmental samples demonstrated its remarkable selectivity and sensitivity at the ultratrace level. Screening assessments performed on water and sediment matrices from eight Portuguese estuaries and coastal waters identified EDC "hotspots." These EDCs mainly come from agricultural and a wide variety of industrial sources, and include pesticides and pesticide metabolites, phenolic derivatives and polycyclic aromatic hydrocarbons, which are included in the lists of priority substances published by international environmental agencies. The estuaries that contained relatively high levels of pesticides were Guadiana, Sado and Mondego, while Minho, Douro and Formosa showed enhanced levels of phenolic derivatives. Dibutyltin and tributyltin, selected as target compounds to be monitored by SPE-LVI-GC-MS in the selected ion monitoring mode, were shown to be widespread contaminants at trace levels in almost all of the sediment matrices assessed. The reliability of the proposed methodology undoubtedly makes it a valuable tool that could replace other analytical strategies currently used to screen for EDCs present in the environment at ultratrace levels.

Chemistry Techniques, Analytical↗

A faster plant stem-water extraction method.

Oxygen and hydrogen isotope ratios of stem water have been used by several studies which relate the ecophysiology of plants to their water source. Undoubtedly, there are several other applications and research areas which could use this type of analysis. However, the most often used methods of extracting stem water are slow, limiting the rate of sampling and consequently preventing a deeper understanding of spatial and temporal plant water source use. We have developed a faster batch method of stem-water extraction and compare it with the most commonly used online method of stem-water extraction. Samples are sealed in 18 cm long ampoules having their extremities placed sample end in a heating block and the condensing end in a cooling block, and allowed to distill overnight. Up to 72 samples can be distilled overnight and sealed the next morning. The isotope ratios of water distilled by the batch method introduced here compared with those from the online method were in excellent agreement. In addition to being faster, this method does not need the monitoring of hot water baths and liquid nitrogen traps during distillation and does not require a complex vacuum system.

Chemistry Techniques, Analytical↗

Rapid circular microfluidic mixer utilizing unbalanced driving force.

This paper proposes a novel rapid circular microfluidic mixer for micro-total-analysis-systems (mu-TAS) applications in which an unbalanced driving force is used to mix fluids in a circular chamber at low Reynolds numbers (Re). The microfluidic mixer has a three-layered structure and is fabricated on low-cost glass slides using a simple and reliable fabrication process. Using hydrodynamic pumps, fluids are driven from two inlet ports into a circular mixing chamber. Each inlet port separates into two separate channels, which are then attached to opposite sides of the 3-dimensional (3-D) circular mixing chamber. The unequal lengths of these inlet channels generate an unbalanced driving force, which enhances the mixing effect in the mixing chamber. Numerical simulations are performed to predict the fluid phenomena in the mixing chamber and to estimate the mixing performance under various Reynolds number conditions. The numerical results are verified by performing flow visualization experiments. A good agreement is found between the two sets of results. The numerical and experimental results reveal that the mixing performance can reach 91% within a mixing chamber of 1 mm diameter at a Reynolds number of Re=3. Additionally, the results confirm that the unbalanced driving force produces a flow rotation in the circular mixer at low Reynolds numbers, which significantly enhances the mixing performance. The novel micromixing method presented in this study provides a simple solution for mixing problems in Lab-on-a-chip systems.

Chemistry Techniques, Analytical↗