Positron emission tomography/computed tomography: protocol issues and options.

Abstract

Combined positron emission tomography/computed tomography (PET/CT) became FDA-approved for clinical use in late 2001. There are several design advantages of combined PET/CT over PET and CT acquired on separate devices, including more accurate CT and PET data co-registration, improved lesion localization, consolidation of imaging studies, and reduced scan times compared to dedicated PET. There are several protocols that can used to scan patients on combined PET/CT devices. Although there is no single "correct" protocol for performing a PET/CT scan, the use of oral and intravenous contrast media may improve the diagnostic value of the CT component. Whether to utilize contrast media depends on important clinical variables, including the specific type of tumor and the likelihood of encountering viable abdominal and pelvic malignancy. This article discusses various protocols pertinent to PET/CT imaging, including how the CT portion of a PET/CT scan can be performed and optimized, as well as PET/CT interpretation and reporting issues.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Todd M Blodgett, Barry M McCook, Michael P Federle. 2006. Positron emission tomography/computed tomography: protocol issues and options.. https://doi.org/10.1053/j.semnuclmed.2005.12.004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗