Abstract
PURPOSE: To evaluate the accuracy of left ventricular volumetric and functional parameters from multi-slice computed tomography using automated analysis software, and to correlate results with those of invasive left ventriculography. MATERIALS AND METHODS: In 145 consecutive patients (mean age, 61 years+/-12) known or suspected to have coronary artery disease, a 16-channel multi-slice computed tomography (Philips Mx8000 IDT 16) was performed using a standard technique. Using short-axis secondary multi-slice computed tomography reformations, we determined end-diastolic and end-systolic left ventricular volumes and ejection fraction with a commercially available analysis software capable of automated contour detection. Conventional left ventriculography was performed according to standard techniques within the following 24 h. Bland-Altman analysis was performed to calculate the limits of agreement and systematic errors between multi-slice computed tomography and conventional left ventriculography. RESULTS: As determined by computer tomography, mean end-systolic (53+/-29 mL) left ventricular volumes had an acceptable correlation with conventional ventriculography (67+/-50 mL; r=0.74; p<0.001) and mean end-diastolic (119+/-33 mL) left ventricular volumes a poor correlation with conventional ventriculography measurements (154+/-69 mL; r=0.41). Left ventricular ejection fraction (57%+/-14 versus 55%+/-14 for conventional ventriculography; r=0.79) showed a very good correlation (p<0.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.2% for ejection fraction) without systematic errors. CONCLUSION: The use of a multi-slice computed tomography with an automatic calculation software has a good correlation with conventional ventriculography findings and could accurately assess left ventricular function, but should not be used for ventricular volumes, because of biased estimations.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Martine Gilard, Pierre-Yves Pennec, Jean-Christophe Cornily, Ulric Vinsonneau, Gregoire Le Gal, Michel Nonent, Jacques Mansourati, Jacques Boschat. 2006-03-27. Multi-slice computer tomography of left ventricular function with automated analysis software in comparison with conventional ventriculography.. https://doi.org/10.1016/j.ejrad.2006.02.010
Cite the original work for its findings. Save a collection to share your selection of sources.