PubMed Health⌕ Search

PubMed · 16569498

Development of a high analytical performance-tyrosinase biosensor based on a composite graphite-Teflon electrode modified with gold nanoparticles.

Abstract

The design of a new tyrosinase biosensor with improved stability and sensitivity is reported. The biosensor design is based on the construction of a graphite-Teflon composite electrode matrix in which the enzyme and colloidal gold nanoparticles are incorporated by simple physical inclusion. Experimental variables such as the colloidal gold loading into the composite matrix, the enzyme loading and the potential applied to the bioelectrode were optimized. The Tyr-Au(coll)-graphite-Teflon biosensor exhibited suitable amperometric responses at -0.10 V for the different phenolic compounds tested (catechol; phenol; 3,4-dimethylphenol; 4-chloro-3-methylphenol; 4-chlorophenol; 4-chloro-2-methylphenol; 3-methylphenol and 4-methylphenol). The limits of detection obtained were 3 nM for catechol, 3.3 microM for 4-chloro-2-methylphenol, and approximately 20 nM for the rest of phenolic compounds. The presence of colloidal gold into the composite matrix gives rise to enhanced kinetics of both the enzyme reaction and the electrochemical reduction of the corresponding o-quinones at the electrode surface, thus allowing the achievement of a high sensitivity. The biosensor exhibited an excellent renewability by simple polishing, with a lifetime of at least 39 days without apparent loss of the immobilized enzyme activity. The usefulness of the biosensor for the analysis of real samples was evaluated by performing the estimation of the content of phenolic compounds in water samples of different characteristics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Carralero, M L Mena, A Gonzalez-Cortés, P Yáñez-Sedeño, J M Pingarrón. 2006-03-29. Development of a high analytical performance-tyrosinase biosensor based on a composite graphite-Teflon electrode modified with gold nanoparticles.. https://doi.org/10.1016/j.bios.2006.02.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques↗

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques↗

Investigating the molecular mechanisms of in-plane mechanochemistry on cantilever arrays.

Free-standing cantilevers, which directly translate specific biochemical reactions into micromechanical motion, have recently attracted much attention as label-free biosensors and micro/nano robotic devices. To exploit this mechanochemical sensing technology, it is essential to develop a fundamental understanding of the origins of surface stress. Here we report a detailed study into the molecular basis of stress generation in aqueous environments focusing on the pH titration of model mercaptohexadecanoic acid self-assembled monolayers (SAMs), using in situ reference cantilevers coated with nonionizable hexadecanethiol SAMs. Semiautomated data analysis and a statistical model were developed to quantify cyclic deprotonation/protonation reactions on multiple arrays. In-plane force titrations were found to have the sensitivity to detect ionic hydrogen bond formation between protonated and nonprotonated carboxylic acid groups in the proximity of the surface pK1/2, which generated a mean tensile differential surface stress of +1.2 +/- 0.3 mN/m at pH 6.0, corresponding to 1 pN attractive force between two adjacent MHA molecules. Conversely, the magnitude of compressive differential surface stress was found to increase progressively with pH >/= 7.0, reaching a maximum of -14.5 +/- 0.5 mN/m at pH 9.0, attributed to enhanced electrostatic repulsion between deprotonated carboxylic acid groups. However, striking differences were observed in the micromechanical responses to different ionic strength and ion species present in the aqueous environment, highlighting the critical role of counter- and co-ions on surface stress. Our findings provide fundamental insights into the molecular mechanisms of in-plane mechanochemistry, which may be exploited for biosensing and nanoactuation applications.

Biosensing Techniques↗