PubMed Health⌕ Search

PubMed · 16570535

Method analysis for optimal continuous imaging using intravascular optical coherence tomography.

Abstract

OBJECTIVES: Optical coherence tomography(OCT)is a high-resolution imaging method that can clearly visualize vessels through the displacement of blood with flushing agents. Continuous imaging methods have not been established. This study investigated optimal methods for continuous OCT imaging. METHODS: Thirty-four arteries with stent implantation (24 peripheral and 10 coronary arteries)in 14 pigs were examined using OCT with a motorized pullback device. Two imaging methods (flush alone by liquid substance and flush with occlusion) were compared. Adequate image acquisition was defined as the entire circumferential intimal layer being detectable within continuous segments. To investigate factors that could influence image quality, stented regions were divided into 4-5 mm segments. RESULTS: The flush with occlusion method provided better OCT images compared to flush alone (flush with occlusion: 60.9%, flush alone: 8.7%, p = 0.0002). Using the flush with occlusion method, the rate of adequate image acquisition was 64.4% and visualization of > 75% intimal circumference was 83.5%. Intravascular ultrasound could detect all stented regions. Segmental analyses found more adequate images were detected in smaller vessels (adequate segment: 3.8 +/- 0.4 mm, inadequate segment: 4.2 +/- 0.8 mm, p < 0.0001) or with centered image wire position (adequate segment: center 35%, inadequate segment: center 14%, p = 0.003). In addition, side branches did not affect image quality. CONCLUSIONS: To acquire continuous OCT images, the flush with occlusion method was more effective compared to flush alone. Moreover, image quality is affected by vessel size and imaging wire position. These results suggest that optimized OCT imaging can provide continuous vessel detection.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Koichiro Asawa, Toru Kataoka, Yoshiki Kobayashi, Takao Hasegawa, Hiroki Nishioka, Hajime Yamashita, Zhaohui Qiu, Shoichi Ehara, Makoto Hirose, Kimio Kamimori, Kenei Shimada, Minoru Yoshiyama, Junichi Yoshikawa. 2006. Method analysis for optimal continuous imaging using intravascular optical coherence tomography.. https://pubmed.ncbi.nlm.nih.gov/16570535/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protocol for Detecting and Sequencing Chikungunya Virus from Field-Collected Mosquitoes.

Arboviral diseases represent a major public health challenge, especially in tropical regions where environmental conditions may favor the proliferation and spread of mosquito vectors. Thus, early and accurate detection of chikungunya virus (CHIKV) in mosquito populations can be a valuable tool for effective surveillance of circulating variants and for identifying new viral introductions. Given the challenges of detecting arboviruses in field-captured mosquitoes, we describe an integrated workflow for CHIKV molecular detection and whole-genome sequencing. This protocol includes mosquito homogenization using a bead-based mechanical disruptor, RNA extraction using TRIzol reagent with minor modifications, molecular screening using CHIKV-specific RT-qPCR, and whole-genome amplification followed by sequencing on Illumina platforms. Despite the protocol being optimized for individual mosquitoes, it results in high-quality RNA suitable for both entomological surveillance and genomic analysis. As this protocol allows recovery of complete CHIKV genomes from mosquito specimens, it can serve as a basis for genomic epidemiology studies, enabling monitoring of viral diversity and lineage dynamics, and facilitating early detection of emerging variants to support timely and targeted public health interventions in endemic and at-risk regions.

Animals↗

Genomic Profiling of Chromatin State Using CUT&Tag.

Alterations in chromatin state, mediated through histone modifications and the incorporation of histone variants, are fundamental to establishing transcriptional networks and cell identity. Recent advances in low-input epigenome profiling methods, such as CUT&Tag and CUT&RUN, have enabled the study of chromatin states from very limited starting materials. In this chapter, we describe procedures for generating CUT&Tag libraries to profile histone modifications and histone variants in early-developing zebrafish embryos.

Animals↗

Relaxin-2: Shaping the Proteomic Landscape of Skeletal Muscle Physiology, Glucose Trafficking, and Mitochondrial Function in Rat.

Relaxin-2 is a hormone with robust beneficial effects on the heart and blood vessels and potential as a therapy for cardiovascular (CV) disease. Considering the interorgan communication between skeletal muscle and heart, and the relation between muscle quality/composition and CV events, we hypothesize that relaxin-2 may regulate skeletal muscle physiology and metabolism. We aim to evaluate the impact of relaxin-2 on the proteome of skeletal muscle from healthy Sprague-Dawley rats. Animals were treated with 0.4&#x2009;mg/kg/day of serelaxin (recombinant form of human relaxin-2) or vehicle (PBS) for 2&#x2009;weeks employing subcutaneous osmotic minipumps. Skeletal muscle protein identification and quantification were performed by LC-MS/MS using a Data-Independent Acquisition (DIA)-Sequential Window Acquisition of All Theoretical Fragment Ion Spectra (SWATH) method. SWATH/MS quantitative analysis identified that relaxin-2 significantly decreased 95 proteins and significantly increased 32 proteins in rat skeletal muscle when compared to control rats. From these, 34 proteins were associated with muscle function, myogenesis, muscle differentiation and/or regeneration, 20 are mitochondrial proteins (six from the complexes of the electron transport chain), and 10 proteins participate in glucose metabolism. Qualitative data-dependent workflow analysis identified 35 proteins exclusive to the skeletal muscle of the relaxin-2-treated group: eight proteins related to processes of skeletal muscle function (size, ion homeostasis or organization of caveolae structures and cytoskeleton) and myogenesis, and two proteins involved in muscle differentiation. Our work highlighted for the first time the role of relaxin-2 in crucial processes of muscle physiology and energetic metabolism, which could influence several processes involved in myopathy and CV.

Animals↗